Regency CS1200 Manuale Utente

Pagina di 32
Regency CS1200  Freestanding Wood Stove
7
INSTALLATION
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS
MEASUREMENTS "FROM UNIT" ARE FROM THE SIDE SHIELDS OF THE STOVE TO A SIDE WALL OR TO A CORNER, AND 
FROM THE REAR HEAT SHIELD TO A BACK WALL
NOTE: Be aware that local Codes and Regulations may override some clearances listed in this manual.
 
      Check with your local inspector.
Residential Installation “C” Vent  (Single Wall)
Unit
From Unit
From Corner
From Flue Center-line
CS1200
A
B
C
D
E
F
13"
11"
8"
26-3/8"
18-1/2"
20-3/4"
Residential  Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from 
the stove collar to the ceiling level.
From Unit
From Corner
From Flue Center-line
CS1200
A
B
C
D
E
F
11"
7"
7"
24-1/2"
14.5"
19-3/4"
Mobile Home Close Clearance (To be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)   
From Unit
From Corner
From Flue Center-line
CS1200
A
B
C
D
E
F
11"
7"
7"
24-1/2"
14.5"
19-3/4"
A
F
F
C
C
B
E
D