Lightolier 2000AICV Dépliant

Pagina di 1
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • I1208
Job Information 
Type:
Job Name: 
Cat. No.: 
Lamp(s): 
Notes:
 
Lytecaster
®
 Recessed Downlighting
  2000AICV
Page 1 of 1 
3 3/4" Aperture Low Voltage MR16 Insulated Ceiling AirSeal
®
 Frame-In Kit
Reflector Trim
Frame-in Kit
Features
1.  Housing: .026” galvanized steel. UL listed for direct contact with thermal 
insulation. AirSeal
®
 housing minimizes air leakage to less than 2 CFM at 1.57 
PSF, which complies with Washington State Model Energy Code (Section 
602.3.3) and reduces heat loss and condensation in ceiling. Access door for 
inspection of junction box.
2.  Mounting Frame: .036” (#20 ga.) galvanized steel. Accommodates ceilings 
up to 1” thick. Four slots are positioned 90° apart to simplify alignment. Push-
in/twist-out rotoclips hold reflector flush to ceiling.
3.  Junction Box: 2”X 4” X 4”;.063” (#16 ga.), galvanized steel. UL listed for 
maximum of 6 No. 12 ga., 90° C through branch circuit conductors. Quick 
release “L” shaped cover for outside access to wiring. Access door inside of 
housing allows easy inspection of wiring without removal of housing. Integral 
cable clamps permit attachment of nonmetallic Romex
®
 or armored cable 
without the need for additional connectors.
4.  Mounting Bars: .059 (#16 ga.) galvanized steel. 13” long bars extend to 27”, 
rotatable and lockable, with integral T-bar tabs. Attach to wood joist or T-bar 
ceiling without need for accessories.
5.  Socket Housing: Aluminum, with lamp adjustment assembly allows 35° 
max. vertical, 358° horizontal adjustment.
6.  Socket: Field replaceable. Two pin socket, pre-wired with #18 SF1 leads to 
junction box.
7.  Thermal Protector: Mounted inside housing. Meets NEC and 
UL requirements.
8.  Transformer: Mounted inside housing, magnetic. 120V pri-mary, nominal 12V 
secondary. Removable from below.
Dimming
Dimming Controls: use only dimmers specifically designed for use with magnetic 
transformers, like Lightolier Onset
®
 Sunrise
®
 series LV or VA, dimmers, or any 
Lightolier Controls dimming systems. Low voltage fixtures may produce audible 
sound when used with dimmers, which may be objectionable in acoustically criti-
cal areas.
Options and Accessories
Mounting Bars: 
 
1976 - 13” set of (4)
Replacement Kit:
Plaster Ceiling Ring:   
1959 - 7/8” depth for wet plaster ceilings.
MR 16 Socket Replacement: 
1975B
Labels
UL (Type I.C., Suitable for Damp Location), I.B.E.W.
Complies with Washington State Air Leakage Requirements as stated in the 
Model Energy Code and the Washington State Energy Code.
Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.
Frame-In Kit 
Reflector Trims   — See Individual Reflector Trim Specification Sheets
 
   
 
           Open Downlight 
 
 
Enclosed
 
   
Aperture Cone 
Satin Cone  Baffles 
Slot 
Pinhole 
Diffuser
2000AICV 
2012 
2008 
2005 
2006 
2011 
2090LV
   
2012NM 
2008NM 
2005WH 
 
 
 
   
2013BKNM 
2010 
2005BNM   
 
   
2013CD 
2010NM 
2005NM
   
2013CDNM 
 
   
2013NM
   
2013BK
   
2013WH
   
2013
   
2013WD
   
2013WDP
Romex
®
 is a registered trademark of General Cable Industries Inc.
US Patent No’s: 5,045,985