INSTRUCTION SHEET NO.
IS:6085
A0103     
PAGE 1 OF 1
FALL RIVER, MASSACHUSETTS, 02720
MONTREAL,  QUEBEC,  CANADA
®
LYTESPAN CONVENIENCE OUTLET IS RATED AT 6 AMPS
MAX., 125 VOLTS. DO NOT EXCEED RATING.
INSTRUCTIONS FOR ATTACHING CONVENIENCE OUT-
LET FITTING TO BASIC TRACK (Single Circuit)
1.
Align BEAD on LYTESPAN TRACK and GROOVE in FITTING
before inserting into LYTESPAN TRACK. See Fig. 1.
2.
Unscrew the TURN KNOB partially and position LEVER.
See Figure1.
3.
To attach FITTING, squeeze BUTTON and KNOB, insert into
LYTESPAN TRACK and release. Tighten TURN KNOB. This
holds FITTING to LYTESPAN TRACK.
4.
To shift FITTING location on the LYTESPAN TRACK, loosen
TURN KNOB slightly, release LEVER and slide to new posi-
tion.
5.
To remove FITTING reverse the procedure in (3), push
TURN KNOB in and allow FITTING to disengage.
6.
FITTING can be left on LYTEPSAN TRACK when not in use
by turning LEVER to disconnect electrically.
INSTRUCTIONS FOR CONVERTING CONVENIENCE OUT-
LET FITTING TO OPERATE ON ADVENT TRACK (2 Circuit)
NOTE:  To insure proper operation of FITTING on Two Circuit 
Lytespan Track, the BLACK SPACER (supplied) must be
used at all times on the plug assembly.
LOWER CIRCUIT, FIG. 3:
Illustrates contacts in low position with spacer 
in place for lower circuit.
UPPER CIRCUIT, FIG. 4 and 5:
To convert FITTING for upper circuit, raise BRASS
CONTACT to high position (as indicated by dotted
line) by pulling CONTACT as high as stop permits and
slipping on BLACK SPACER as shown in Fig. 4 and 5.
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local
regulations.  To assure full compliance with local codes and regulations, check with your local
electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box
before proceeding.
Retain these instructions for maintenance reference.