INSTALLATION  INSTRUCTIONS  FOR  12V  LOW  VOLTAGE
AND  120V  REMODELER
INSTRUCTION  SHEET
07-01/Rev-03
ISF:300
A. CEILING:
1. Cut  an  opening  as  indicated  above.  (Fig.1)
Note:  Ensure  that  there  is  nothing  to  obstruct  the
installation  in  the  ceiling.
B. WIRE-IN:
1. Open  junction  box  cover.  (Fig.2)
2. Insert  the  supply  lead  into  the  junction  box  with  a
BX  connector  (not  included).
3. Ground  the  fixture.
4. Connect  the  white  leads  (NEUTRAL)  together,  and
the  black  leads  (120V)  together.  (Fig.3,  4  or  5)
5. Close  cover.  (Fig.2)
Note:  Be  careful  not  to  pinch  leads.
C. HOUSING:
1. Slide  the  power  pack  and  the  housing  together  into
the  ceiling.  Snap  into  place.  (Fig.6)
D. RESIDENCE MOUNTING FASTENERS
1. Screw  both  fasteners  screws.  (Fig.8)
OR
303MRE  MOUNTING  FASTENERS:
1. Place  (3)  holding  springs,  in  the  T  slots.  Slowly
push  downward  using  a  short  handle  screwdriver,
until  trim  is  flush  with  ceiling,  solidify  with  screws
(3)  (included),  (Fig.7)
ATTENTION:  Insure  that  the  spring  is  placed
correctly  in  the  T  slot,  nice  and  straight  then  push
down  slowly.  The  spring  does  not  have  to  be
lowered  completely  in  the  slot.
CAUTION: The housing must not be used for
temporary lighting, a protective shield is
required for the lamp.
E. TRIM:
1. Install  the  trim  using  the  appropriate  instruction
sheet.
F. TRANSFORMER / REPLACEMENT:
(Models  301MRE,  303MRE,  401MRE)
Note:  Before  performing  maintenance  on  the
transformer,  make  sure  that  the  electrical  supply  to
the  fixture  is  turned  off.
1. Remove  the  junction  box  cover  and  disconnect  all
wiring  connected  to  the  transformer.  (Vig.9)
2. The  transformer  is  held  by  double  sided  tape,  rotate
with  screwdriver  under  the  transformer  to  loosen  it.
(Fig.9)
3. Complete  the  connections  (Fig.5)  following  the
wiring  diagram.
NOTE: WARNING RISK OF FIRE
Transformer  contains  fixture  thermal  protector.  Use  only
replacement  transformer  obtained  from  LIGHTOLIER.
DIA*  =  CEILING  CUT-OUT
300MR  =  3-3/4"  (95mm)  Dia*
400MR  =  4-3/4"  (121mm)  Dia*
1"  Max.  ceiling  thickness
300ES  =  3-3/4"  (95mm)  Dia*
1"  Max.  ceiling  thickness
301MRE  =  3-3/4"  (95mm)  Dia*
401MR  =  4-3/4"  (121mm)  Dia*
1"  Max.  ceiling  thickness
303MRE  =  3-3/4"  (95mm)  Dia*
1/2"  Max.  ceiling  thickness
SUPPLY
LEAD
FIG.1
FIG.2
JUNCTION
BOX
BX
CONNECTOR
JUNCTION
B O X
FIG.3
(MR)
INPUT  (120V)
NEUTRAL  (white)
GROUND
LAMP
LOW  VOLTAGE
TRANSFORMER
WHITE
BLACK
THERMAL
PROTECTOR
JUNCTION
B O X
THERMAL
PROTECTOR
LAMP
FIG.4
(ES)
INPUT  (120V)
GROUND
NEUTRAL  (white)
BLACK
NEUTRAL
WHITE
WHITE
BLUE
FIG.5
(MRE)
FIG.7
SCREWS
FASTENERS
SCREW
"T"
SLOTS
RETAINING
SPRINGS
HOUSING
FIG.8
CEILING
COVER
FIG.6
POWER PACK
HOUSING
300MR  /  400MR
300ES
301MRE  -  401MRE
303MRE
JUNCTION  BOX
LAMP
LOW  VOLTAGE
TRANSFORMER
THERMAL
PROTECTOR
NEUTRAL  (white)
GROUND
BLUE
BLACK
BLACK
INPUT  (120V)
NEUTRAL  (white)
READ  AND  UNDERSTAND  THESE  INSTRUCTIONS  BEFORE  INSTALLING  FIXTURE
This  fixture  is  intended  for  installation  in  accordance  with  National  Electrical  Code  or  Canadian  Electrical
Code  (as  applicable)  and  local  regulations.  To  ensure  full  compliance  with  local  codes  and  regulations,  check  with  your  local
electrical  inspector  before  installation.  To  prevent  electrical  shock,  turn  off  electricity  at  fuse  box  before  proceeding.
Retain  these  instructions  for  maintenance  reference.