Lightolier SH Dépliant

Pagina di 2
Job Information 
Type:
"JSQPSU3PBE 'BMM3JWFS ."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #
Lighting Systems
 Silhouette
®
 SH
1BHFPG
%JSFDU-PVWFS-JHIU5QFS'PPU /PNJOBM 4FDUJPO
Mounting & Joiner Block Accessories
“X” Block with Suspension
SX36WH (white)
SX36AL (aluminum)
Inline block available (SI36WH or SI36AL).
“L”Block with Suspension
SL36WH (white)
SL36AL (aluminum)
“T” Block with Suspension
ST36WH (white)
ST36AL (aluminum)
Power Feed End Set
SE36WH (white)
SE36AL (aluminum)
Cable Assembly
SC36
Sample Run
Fixture Lengths & Mounting Locations
4-Foot Joiner
4-Foot Joiner
8-Foot Joiner
5/8” (1.59cm)
1-1/4” (3.18cm)
Power Feed
End Set
Cable
Assembly
8-Foot Joiner
8-Foot Joiner
96” (243.84cm)
48” (121.92cm)
48” (121.92cm)
96” (243.84cm)
96” (243.84cm)
20’ 1/8” (609.92cm)
8” (20.32cm)
4”
(10.16cm)
4” (10.16cm)
3.4”
(8.64cm)
8”
(20.32cm)
4”
(10.16cm)
4.6” (11.68cm)
4” (10.16cm)
CANDLEPOWER
ZONE      0      22        45          67    
90
DEG.
CANDELAS
180
147
147
147
147
147
175
148
147
147
143
143
165
142
135
129
124
122
155
130
117
113
114
117
145
110
97
103
116
120
135
80
76
93
109
115
125
56
61
86
99
102
115
23
35
61
81
87
105
14
26
57
80
75
95
7
26
57
77
51
90
11
34
64
83
46
85
29
48
77
96
67
75
85
98
112
136
137
65
137
185
239
201
188
55
217
315
451
486
468
45
395
511
634
749
772
35
620
758
832
963
1031
25
823
960
1051
1127
1155
15
979 1057
1166
1246
1248
5
1079 1092
1118
1132
1136
0
1099 1099
1099
1099
1099
2,000
700
500
400
200
FOOTCANDLE
20
30
50
70 100
1
2
3
4 5
7
10
20
30 40 50
70
100
200
ROOM AREA IN SQUARE FEET
NUMBER OF FIXTURES REQUIRED
300
1,000
100
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
WALL REFLECTANCE
70
50
30
70
50
30
50
30
10
0
63
63
63
60
60
60
56
56
56
1
58
56
54
56
54
52
50
48
47
2
54
50
47
52
48
46
45
43
41
3
50
45
42
48
44
40
41
38
36
4
46
41
37
44
40
36
37
34
32
5
43
37
33
41
36
32
34
31
28
6
40
34
30
39
33
29
31
28
25
7
37
31
27
36
30
26
28
25
23
8
35
28
24
33
27
24
26
23
20
9
32
26
22
31
25
21
24
21
18
10 29
23
19
28
22
18
21
18
15
20% FLOOR CAVITY REFLECTANCE
ROOM CA
VITY RA
TIO
Quick Calculator
1. Find room area on 
vertical axis.
2.  Move across chart to 
footcandle curve.
3. Move down to 
horizontal axis and 
read number of 
fixtures required.
DISTRIBUTION
Zone
Lumens
% Lamp
% Luminaire
0-90
2666
46.0
84.7
90-180
482
8.3
15.3
0-180
3148
54.3
100.0
Calculations are for 28 watt T5 lamps, for 54 watt T5 lamps multiply by 1.7
90˚
85˚
95˚
105˚
75˚
65˚
55˚
115˚
125˚
180˚  175˚      165˚        155˚          145˚               135˚
0˚    5˚        15˚           25˚            35˚                 45˚
500
750
250
1000
1250
0
90
˚
0
˚
250
Performance
REPORT NO: LRL 299-1C
CAT NO:  SH24I281WH
LAMPS: 2 F28T5
LUMENS: 2900
EFFICIENCY: 54.3
%
CANDLEPOWER CURVE