Lightolier IS:406BLS Dépliant

Pagina di 1
631 Airport Road, Fall River, MA 02720
COMPANY 
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE 
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.  To 
assure full compliance with local codes and regulations, check with your local electrical inspector before  
installation.  To prevent electric shock, turn off electricity at fuse box before proceeding. 
Retain these instructions for maintenance reference. 
IS:406BLS
 
INSTRUCTION SHEET NO. 
A0105 
Page 1 of 1 
INSTRUCTIONS FOR 6.5” PENDALYTE™ SERIES TRACK MOUNT TO LYTESPAN ® TRACK SYSTEM SUSPENSION 
KITS. FOR USE WITH LYTESPAN TRACK SYSTEMS ONLY. 
NOTE: Not for use with ProSpec track. 
WARNING: TO PREVENT ELECTRIC 
SHOCK, TURN OFF POWER TO TRACK. 
INSTALLATION INTO TRACK (fig. 2) 
1.
Turn off power to TRACK. 
2.
Insert POWER STEM into track. The STEM LEVER must be on the 
same side as the track bead. See fig. 2. 
3.
Rotate suspension stem 90° clockwise using STEM LEVER. STEM 
LEVER should be parallel to TRACK. 
4.
To remove: rotate SUSPENSION STEM 90° counterclockwise using 
STEM LEVER. 
CAUTION: MAXIMUM WATTAGE AS MARKED ON LUMINAIRE MUST NOT BE EXCEEDED. 
Fig. 2 
TRACK 
STEM LEVER 
BEAD 
POWER STEM INSTALLATION (fig. 1) 
1.
Slide STEM and BUSHING over POWERCORD. Align end of 
POWERCORD with top of BUSHING tighten SET SCREW to secure 
POWERCORD. 
2.
Twist stripped ends of POWERCORD wires an attach using CONTACT 
SCREWS: attach hot (black POWERCORD lead to long BRASS 
CONTACT, attach neutral (white) POWERCORD lead to short NICKEL 
CONTACT, attach POWERCORD ground lead (green) to BODY with 
green CONTACT SCREW. 
3.
Slide STEM up over contacts and secure to BODY using #4 SCREWS. 
#4 SCREWS 
CONTACT 
SCREWS 
Fig. 1 
BRASS CONTACT 
BUSHING 
SET SCREW 
STEM 
NICKEL CONTACT 
BODY 
POWERCORD