Ordering Information
Family
T = T8
6 = Direct/
Indirect
03
CN           
T
6
BSL
03 = 3 Light
CN = Cutout  
  w/baffles
04 = 4’
08 = 8’
12 = 12’
C = Custom Color
W = Standard
 
  White
Distribution
Lamp Type
No. of Lamps
Housing
Module Length
Wiring 
Voltage
Ballast
Finish
Weight = 3.0 lb/ft
angled lamp
Lighting Systems
 
Baselyte-BSL2
Page 1 of 8   
3 Light T8 Direct/Indirect
Specifications
Features
1.  Housing: die-formed 20ga. cold rolled steel
2.  End Set: die-cast metal with baked powder coat finish
3.  Lamping: three T8 lamps
4.  Configuration: 4’, 8’ and 12’ module lengths or continuous rows
5.  Ballasts: electronic 120V or 277V
Finish
High-quality white powder coat with textured matte finish.
Custom colors available. Consult factory.
Mounting
Aircraft cable gripper is tamper-resistant and provides infinite vertical
adjustment capability. Aircraft cable, crimp and cable gripper independently
tested to meet stringent safety requirements.
Electrical
All luminaires are factory pre-wired to module ends with quick-wire 
connectors.
Joints & Intersections
Self-aligning joining system with hands-free pre-joining wire access.
Labels
UL, CSA standards.
Individual Fixtures
1.  Determine the number of individual modules required
2.  Order one end set per module
3.  Order one non-power mount per module
4.  Order one power mount per module
Continuous Rows*
1.  Determine run length
2.  Order the appropriate number and length of modules for complete run 
3.  Order one end set for each run
4.  Order one non-power mount for each module
5.  Order one power mount per run
6.  Order one joiner per module minus one (e.g. 3 modules requires 2 joiners)
*Note: Some runs may require additional power mounts. Please see the ‘Run 
Configuration’ table on next page for more details.
1 = 120V
2 = 277V 
= Standard  
<20% THD
= Standard  
<20% THD  
w/fusing
= <10% THD,  
Instant Start
= <10% THD,  
Instant Start  
w/fusing
= <10% THD,  
Program Start
= <10% THD,  
Program Start  
w/fusing    
1 = 1cct.
2 = 2cct. 
= 1cct. w/EC/NL
= 2cct. w/EC/NL
5 = 1cct. w/EM Battery
6 = 2cct. w/EM Battery
7 = 1cct. w/Dimming
= 1cct. w/1cct.  
Thru wire
9 = 2cct. w/1cct.  
Thru wire
Note: Please consult 
wiring section of spec
sheets for more
wiring options.
Ordering Instructions