Lightolier C12 Dépliant

Pagina di 2
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
a Genlyte company
631 Airport Road, Fall River, MA 02720 
FIG. 4 
INSTRUCTIONS FOR INSTALLING C12E28V SERIES DOWNLIGHT 
REFLECTOR TRIM
 
1.
  Attach SOCKET CUP to REFLECTOR ASSEMBLY by aligning (3) SCREWS 
with key slots in REFLECTOR NECK, then tighten screws. (Fig. 1) 
 
2.
  Position REFLECTOR ASSEMBLY into MOUNTING RING of Frame-In  
 
Kit or Cylinder, align (4) FLATS in REFLECTOR ASSEMBLY with (4)  
 
CONE RETAINING SPRINGS, and align REFLECTOR SPRINGS with  
 
UPPER SLOTS in MOUNTING RING (Fig. 1 & 2). Then raise REFLECTOR 
ASSEMBLY, to snap in place. (FIG. 1) 
 
3.
  Before lamping, make sure power is disconnected to fixture.  
Install lamp into lampholder. 
 
4.
  Install COVER GLASS (required for enclosed lamp rated  
fixture), line-up the edge of COVER GLASS with one spring 
opposite notch on REFLECTOR ASSEMBLY and gently  
push glass outward, then lift glass upward into position. 
Rotate COVER GLASS so that NOTCH in COVER GLASS 
is away from NOTCH in REFLECTOR ASSEMBLY. (Fig. 1 & 3) 
 
5:  Hook SAFETY BEAD CHAIN onto BEAD CHAIN COUPLER.  
Position CONE so that bead chain is about horizontal, then push  
CONE up into MOUNTING RING, then turn CONE clockwise  
slightly for tight fit onto ceiling.  CONE RETAINING SPRINGS will  
hold cone in place. (Fig. 1 & 4) 
 
TO RELAMP 
 
Disconnect power to fixture, then reverse 
installation  
instructions above. 
 
TO INSPECT AND REPLACE BALLAST 
Disconnect power to fixture. Remove Cone. Detach REFLECTOR  
ASSEMBLY by disengage REFLECTOR SPRINGS, move it to side  
of fixture in the plenum, or in cylinder, remove from cylinder. See 
IS:C4-C12 (Frame-In Kit), and IS:C12CS (Cylinder), for ballast 
replacement. After service reverse Installation steps. 
 
Care and Maintenance of REFLECTOR TRIM finish
 
If handling of REFLECTOR TRIM with anodized finish is required, the use  
of clean white or plastic film gloves is recommended to avoid fingerprints.  
Anodized surfaces can be cleaned by the following methods: 
1.  Wipe off with a soft, clean, dry, lint-free cloth. 
2.  Wipe off with a soft clean cloth dampened in mild detergent solution. 
3.  Rinse, then wipe dry with lint-free cloth or paper towel. 
4.  Wipe off with a clean cloth dampened with a solution of wetting agent  
and water (such as 2 oz. Per gallon “Pluronic L62-LF” by Wyandotte  
Products). Wipe dry. 
5. 
Use a liquid wax such as Glass Wax
®.  Avoid gritty cleaning agents.
 
FIG. 1 
FIG. 2 
FIG. 3 
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.  To 
assure full compliance with local codes and regulations, check with your local electrical inspector before 
installation.  To prevent electric shock, turn off electricity at fuse box before proceeding. 
Retain these instructions for maintenance reference.
INSTRUCTION SHEET NO.
IS:C12 
Page 1 of 2
A1204 
INSTALLATION PROCEDURE FOR: 12” DIA. H.I.D. C12 SERIES REFLECTOR TRIM TO 
C12 SERIES FRAME-IN KIT AND C12CS/C12CW CYLINDER (ORDER SEPARATELY) 
IF A NON-IC TYPE RECESSED FRAME-IN KIT IS USED,  DO NOT INSTALL INSULATION ABOVE NOR WITHIN 
3 INCHES (76mm) OF ANY PART OF THE LUMINAIRE (LIGHTING FIXTURE) 
WARNING: 
USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER.  USE OF OTHER MANUFACTURES’ REFLECTOR 
TRIMS MAY VOID THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.