Lightolier FBP30ST Dépliant

Pagina di 1
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • C0308
Job Information 
Type:
Job Name: 
Cat. No.: 
Lamp(s): 
Notes:
 
FBP Series Fluorescent Emergency Ballast
 
FBP30ST
Page 1 of 1 
One or Two Lamp Operation 3,500 Lumens Self-Test Diagnostics
Lightolier is a Philips group brand
Complete Fixture consists of ballast unit. Select options and accessories below.
Model # 
Max. Lumens 
Lamp Operation
FBP30ST 
3,500 
One or Two
The FBP Series quickly converts standard fluorescent luminaires into emergency luminaires.
16.3”
(41.4cm)
5.6”
(14.2cm)
1.7”
(4.3cm)
Features
1.  Lamp Operation: Operates the following lamp types: T8 linear fluorescent, 
T12 linear fluorescent, T9 circline, T12 U-bent, T5 long compact fluorescent, 
compact 4 pin fluorescent. See Lamp Operation and Performance table for 
specific lamp performance and operation.
2.  Illumination: Provides 90 minutes of emergency illumination, and produces 
a maximum of 3,500 lumens initial emergency light output. Can be used with 
most 17w to 215w (2’ - 8’) T8, T10 or T12 fluorescent lamps without integral 
starters including U-shaped, HO, VHO, circline, energy saving, and 4 pin com-
pacts. It is also compatible with most 1, 2, 3 and 4-lamp electronic, standard, 
energy saving and dimming AC ballasts.
3.  Housing: Constructed of 20 gauge steel with a white high temperature    
powder coat paint finish. Slim housing allows for wireway channel mounting 
on most recessed luminaires.
4.  Electronics: 120/277 VAC dual voltage input with surge-protected, solid-
state circuitry. Charging system is complete with AC indicator lamp and test 
switch.
5.  Self-Test: The diagnostics circuit constantly monitors battery voltage and 
charging current, and will communicate a fault by flashing the status indica-
tor lamp.  An automatic discharge test is also performed for 30 seconds, 
every 30 days and for 90 minutes every 12 months.  This automatic test 
satisfies the functional period test required by NFPA 101.
6.  Battery: Maintenance free, sealed nickel cadmium battery has an estimated 
service life of 10 years, and an operating temperature range of 32°F (0°C) to 
131°F (55°C). 
7.  Input Power Requirements: 8 watts max.
8.  Warranty: Electronics: 5 years; Battery: 5 years.
Code Compliance
UL 924 listing pending.
Options
EX = Special Input Transformer for 220 VAC/50 Hz, 240 VAC/50Hz. Contact 
factory for other input voltages and frequencies. 
Accessories
CCAPS = Wire bundle cover for mounting external to luminaire.
RTS = Single gang aluminum faceplate pre-drilled to accommodate remote 
installation of test switch and pilot light.
Nickel Cadmium Battery
Lamp Operation and Performance
   
 
 
Non-Emer.   Emer. Op.
   
  
 
Op. Max.  
Max.  
Emer. 
 Lamp 
Watt. 
Non-Emer. 
Lumen 
Lumen 
Lamp
  Type 
Type 
Base 
Output 
 Output 
Operation
 F40/34T12 
34-40  G13/Med Bi-Pin 
2900 
3000 
One or Two
 F40T12/U 
40 
G13/Med Bi-Pin 
3100 
3000 
One or Two
 F48T12HO 
60 
R17D/Recessed 
4050 
3000 
One
 F96T12HO/VHO  95-215  R17D/Recessed  8800/15200 
3000 
One
  F25T8 
25 
G13/Med Bi-Pin 
2200 
2500 
One or Two
  F32T8 
32 
G13/Med Bi-Pin 
3000 
3000 
One or Two
 F32T8/U 
32 
G13/Med Bi-Pin 
2700 
3000 
One or Two
  F40T8 
40 
G13/Med Bi-Pin 
3700 
2500 
One
  F96T8 
59 
FA8/Single-Pin 
5700 
3000 
One
 F39/36BX 
39 
2G11/4--Pin 
2900 
3000 
One or Two
 F40/30BX 
40 
2G11/4--Pin 
3200 
2000 
One
 F42TBXT4 
42 
GX24Q-4P 
3200 
3200 
One or Two
Notes: 
1.  Maximum non-emergency lumen output can vary based on lamp manufacturer, ambient 
operating temperature, and ballast manufacturer.
2.  Maximum emergency lumen output is based on total output of one or two lamps, and 
can vary based on lamp manufacturer and ambient operating temperature.
3.  Maximum emergency lumen output is supported for a full 90 minutes of operation.
4.  Consult factory for compatibility, operation and performance of lamp types not listed.