Lightolier FBP700L Dépliant
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • B0308
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • B0308
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
FBP Low Profile Fluorescent Emergency Ballast
FBP700L
Page 1 of 1
One Lamp Emergency Operation, 650 Lumens
Lightolier is a Philips group brand
Features
1. Lamp Operation: Operates the following lamp types: one 13-54w bi-pin T5/
T5 HO lamp, one 18-55w 4-pin long compact lamp, one 17-55w bi-pin T8-HO
lamp. It is also compatible with most 1, 2, 3 and 4-lamp electronic and dim-
ming AC ballasts. See Lamp Operation and Performance table for specific
lamp performance and operation.
lamp. It is also compatible with most 1, 2, 3 and 4-lamp electronic and dim-
ming AC ballasts. See Lamp Operation and Performance table for specific
lamp performance and operation.
2. Illumination: Provides 90 minutes of emergency illumination, and produces a
maximum of 650 lumens initial emergency light output.
3. Housing: Constructed of 22 gauge steel with a high temperature powder
coat finish. Housing allows for housing frame mounting on most recessed
luminaires.
luminaires.
4. Electronics: 120/277 VAC dual voltage input with solid-state circuitry.
Charging system is complete with AC indicator lamp and test switch.
5. Battery: Maintenance free, high temperature, sealed nickel cadmium bat-
tery has an estimated service life of 10 years, and an operating temperature
range of 32°F (0°C) to 131°F (55°C)
range of 32°F (0°C) to 131°F (55°C)
6. Input Power Requirements: 2.0 watts max.
7. Warranty: Electronics: 5 years; Battery: 5 years.
7. Warranty: Electronics: 5 years; Battery: 5 years.
Code Compliance
UL 924 listed.
National Electrical Code (NEC).
NFPA70 and NFPA101 Life Safety Code and Illumination Standards.
OSHA Safety Code Standards
National Electrical Code (NEC).
NFPA70 and NFPA101 Life Safety Code and Illumination Standards.
OSHA Safety Code Standards
Options
EX = Special Input Transformer (specify voltage and frequency)
DL = Damp Location
DL = Damp Location
Complete Fixture consists of ballast unit. Select options and accessories below.
Model #
Max. Lumens
Lamp Operation
FBP700L
650
One
Lamp Operation and Performance
LINEAR
WATTAGE
BASE
EMERGENCY
LAMPS
TYPE
LAMP OPERATION
Rapid, Instant, Energy Saving
30-40
Single-Pin
One
T8 through T12
Bi-Pin
(2’ - 4’)
Rapid, Instant, T8, T8 HO
17-55
Single-Pin
One
(2’ - 4’)
Bi-Pin
T5
28
Bi-Pin
One
T5, T5 HO
13-54
Bi-Pin
One
(2’-5’)
COMPACT
WATTAGE
BASE
EMERGENCY
LAMPS
TYPE
LAMP OPERATION
T5 Long Compact
30-32
2G11
One
4-Pin
T5 Long Compact
18-55
2G11
One
4-Pin
18.5”
(47.0 cm)
18.1”
(46.0 cm)
1.17”
(3.0 cm)
.73”
(1.9 cm)
1.18”
(3.0 cm)