This drawing provides a 
general illustration of the 
DMX Input/Output panel of 
a lighting fixture.  
Universal DMX
 
Controller
 
Continue the link 
C AB L E  C O N N EC T O R S  
Cabling must have a male XLR connector on one end and a female XLR connector on the other end. 
CAUTION 
Do not allow contact between the common and the fixture’s chassis ground. 
Grounding the common can cause a ground loop, and your fixture may perform 
erratically. Test cables with an ohm meter to verify correct polarity and to make sure 
the pins are not grounded or shorted to the shield or each other. 
3 - PI N   T O   5 - PI N   C O N V ER S I O N   C H AR T  
Note! 
If you use a controller with a 5 pin DMX output connector, you will need to use a 5 
pin to 3 pin adapter. CHAUVET Model No: DMX5M, or DMX5F. 
The chart below details a proper cable conversion: 
3
 
P
IN TO 
5
 
P
IN 
C
ONVERSION 
C
HART
 
Conductor 
3 Pin Female (output) 
5 Pin Male (Input) 
Ground/Shield 
Pin 1 
Pin 1 
Data ( - ) signal 
Pin 2 
Pin 2 
Data ( + ) signal 
Pin 3 
Pin 3 
Do not use 
 
Pin 4 
Do not use 
 
Pin 5 
Setting up a DMX Serial Data Link  
1.  Connect the (male) 3 pin connector side of 
the DMX cable to the output (female) 3 pin 
connector of the controller.   
2.  Connect the end of the cable coming from 
the controller which will have a (female) 3 
pin connector to the input connector of the 
next fixture consisting of a (male) 3 pin 
connector.  
3.  Then, proceed to connect from the output 
as stated above to the input of the following 
fixture and so on. 
CHAUVET Certified DMX Data Cables 
Order Code 
Description 
DMX1.5   
DMX Cable 1.5m/4.9ft 
COMMON 
DMX + 
DMX
 - 
INPUT 
OUTPUT 
1 
3 
2 
1 
3 
2 
1 
3 
2 
Resistance 120 
ohm 1/4w between 
pin 2 (DMX -) and 
pin 3 (DMX +) of 
the last fixture. 
Termination reduces signal errors. To 
avoid signal transmission problems 
and interference, it is always 
advisable to connect a DMX signal 
terminator.
 
DMX connector configuration