Inserting/Exchanging rotating gobos 
 
Open the cover by loosening the fastening 
screw at the sides of the cover. Remove 
the “O” ring w ith tw eezers if available, 
insert the new gobo and replace  the “O” 
ring.  
 
 
 
 
 
 
Lamp replacement
 
 
Because of its high internal pressure, there might be a risk that the Discharge lamp 
could explode during operation. The lamp emits intense UV radiation which is 
harmful to the eyes and skin. The high luminance of the arc can cause severe 
damage to the retina if you look directly into the lamp source. 
Alw ays switch off the main supply and never handle the lamp or luminaries w hen 
it is hot. 
Do not touch the bulb with bare hands. If this happens, clean the lamp with 
alcohol and w ipe it with a lint free cloth before installation. 
The lamp generates UV radiation. Never operate the lamp without appropriate 
shielding. 
When burning, the lamp operates at high pressure and there is a slight risk of arc 
tube rupture. The risk increases w ith age, temperature and improper handling of 
the lamp. Do not use the lamp any longer than its specified life.  
Make sure the lamp is located in the 
center of the reflector for the best spot. 
Adjust lamp position by screws A, B 
and C. 
 
 
When replacing lamp, please wait 15 minutes after 
pow ering dow n to allow  the unit cool dow n! 
CAUTION! 
Sw itch off device before 
exchanging gobos or colors. 
CAUTION! 
Never unscrew the screws of the 
rotating gobo as the ball bearing will 