General Troubleshooting 
 
Symptom 
Solution(s) 
Fixture has no pow er 
Check for pow er on Mains. 
Check fixture’s fuse. 
Lamps cuts off sporadically  
Possible bad lamp or fixture is overheating. Check the fan. Lamp may be at end of its 
life. 
Motor movements are jerky or 
jumpy 
Possible bad motor driver or sensors. 
Beam is very dim 
Clean optical system or replace lamp. 
Fixture is on but there is no 
movement to the audio 
Adjust the audio sensitivity pod. 
Fixture does not respond to DMX  1.
 
DMX LED should be on. If it is not, check the DMX connector and cables for 
proper contact. 
2.
 
If the DMX LED is on and does not respond to the channel, check the address 
settings and DMX polarity. 
3.
 
If you have intermittent DMX signal problems, check the pins on connectors or 
on PCB of the unit or the previous one. 
4.
 
Use another DMX controller to rule out controller issues.  
5.
 
Check if the DMX cables run near or run alongside high voltage cables that may 
cause damage or interference to DMX interface circuit.  
6.
 
Wrong DMX address in the unit. Set the proper address. 
Some units do not respond to the 
Easy Controller 
1.
 
You may have a break in the DMX cabling. Check the LED for the response of 
the master/ slave mode signal. 
Does not respond to sound 
1.
 
Check the unit that is not receiving DMX signal. 
2.
 
Check microphone to see if it is good by tapping the microphone 
A channel is not w orking w ell 
1.
 
The stepper motor might be damaged or the cable connected to the PCB is 
broken. 
2.
 
The motor’s drive IC on the PCB might be out of condition. 
If pan belt is broken 
 
1.
 
Turn off the main pow er.
 
 
2.
 
Unscrew  all the screw s (A) and open 
the base-housing cover (B). 
3.
 
Unplug all the connect w ires (C) 
from the arm to PC board and 
igniter. 
4.
 
Unscrew  (D) screws to release 
bridge (E). 
5.
 
Unscrew  the (F) screw s that connect 
the axis gear (G). 
6.
 
Change a new  belt (H) by going 
through all connect ing w ires from 
the base, and through the bridge to 
the correct position.  
7.
 
Set the gear axis back to the bridge 
and screw it. Note: do not press the 
belt. 
8.
 
Put the belt around the axis gear and 
motor gear. 
9.
 
Plug all the connect w ires (C) that 
form the arm to PC board and 
igniter. 
10.
 
Adjust the pan home position. 
11.
 