Chauvet SCAN LED 100 Manuale Utente

Pagina di 17
 
5. Appendix 
11 
11/19/2010 11:07 AM  
 
5.
 
A
PPENDIX
 
 
 
General Troubleshooting 
 
 
 
S
YMPTOM
 
P
OSSIBLE 
C
AUSE
(
S
) P
OSSIBLE 
A
CTION
(
S
Breaker/Fuse 
keeps blowing 
• Excessive circuit load 
•  Check total load placed on the 
electrical circuit. 
•  Short circuit along the power 
wires 
•  Check for a short in the electrical 
wiring (internal and/or external). 
Device does not 
power up 
• No power 
•  Check for power on Mains. 
•  Loose power cord 
•  Check power cord 
Fixture is not 
responding to DMX 
•  Wrong DMX addressing 
•  Check Control Panel and unit 
addressing  
•  Damaged DMX cables 
•  Check DMX cables 
•  Wrong polarity settings on the 
controller 
•  Check polarity switch settings on 
the controller 
•  Loose DMX cables 
•  Check cable connections 
•  Faulty DMX interface 
•  Replace DMX input 
•  Faulty Main PCB 
•  Replace Main PCB 
Loss of signal 
•  Non DMX cables 
•  Use only DMX compatible cables 
• Bouncing signals 
•  Install terminator as suggested. 
•  Long cable / Low level signal 
•  Install amplifier right after fixture 
with strong signal.  
•  Too many fixtures 
•  Install an optically coupled DMX 
splitter after unit #32. 
•  Interference from AC wires 
•  Keep DMX cables separated from 
power cables or black lights. 
 
 
 
 
If you still have a problem after trying the above solutions, please contact CHAUVET® 