NuTone 744SFLNT Manuale Utente

Pagina di 12
Page 1
MODEL 744SFLNT  
!
HUMIDITY SENSING RECESSED
FLUORESCENT FAN / LIGHT
READ AND SAVE THESE INSTRUCTIONS
CLEANING & 
MAINTENANCE
Installer: Leave this manual 
with the homeowner.
To clean trim ring / baffle: Vacuum with a 
soft brush attachment or remove trim ring / 
baffle and clean with a soft cloth.
SENSOR CLEANING
The humidity sensor is mounted in the trim 
ring/baffle. The  sensor  will  operate  most 
reliably when cleaned occasionally as follows:
1.  Disconnect power at service entrance.
2.  Remove  the  trim  ring/baffle.  Use  a  dry 
dustcloth,  clean  toothbrush,  or  lightly 
vacuum  to  clean  sensor  and  grille. 
DO  NOT  USE  ABRASIVE  CLOTH, 
STEEL WOOL  PADS,  OR  SCOURING 
POWDERS.
3.  DO NOT USE cleaning sprays, solvents, 
or water on or near the sensor!
To clean inside of housing: Remove trim 
ring  /  baffle  and  vacuum  inside  of  housing 
with a soft brush attachment.
Motor is permanently lubricated. Do not oil or 
disassemble motor.
See  “Service  Parts”  section  for  a  list  and 
illustrations of service parts.
OPERATION
The light, fan and humidity control can be operated 
together or independently using multi-function switch 
wall controls.
•  Use a 3-function control to independently operate 
light, fan and humidity control.
•  Use a 2-function control to independently operate 
light and humidity control. For fan operation see 
MANUAL ON WITH TIMED OFF section below.
•  Use a 2-function control to independently operate 
light and fan. Wire humidity control direct to insure 
humidity control is always on.
See “Connect Wiring”  section  for  various  wiring 
options.
Do not use a dimmer switch control to operate 
light, fan or humidity control.
SENSOR OPERATION
This humidity-sensing
 
fan responds to: (a) rapid to 
moderate humidity increases and (b) humidity above 
a 50%-100% relative humidity set-point. (a) and (b) 
are set with “SENSITIVITY” adjustment. Fan may 
occasionally turn on when environmental conditions 
change. If the fan continuously responds to changing 
environmental conditions, “SENSITIVITY” adjustment 
may be required (see section below).
STATUS INDICATOR
This indicator can only be seen by looking directly at 
it. Normal mode is 5-seconds  on and off. If it blinks 
rapidly  for  5-seconds  and  then off, check  sensor 
connections on trim ring/baffle and fan housing. 
MANUAL ON WITH TIMED OFF
For odor or vapor control, the fan can be energized 
by cycling its wall-mounted switch if one is installed. 
Once the fan has been turned on in this manner, it 
will remain on for the set “TIMER” period.
To manually energize the fan:
1.  Go to Step 2 if switch is already on; otherwise, 
turn switch on for more than 1 second.
2.  Switch off for less than 1 second.
3.  Switch back on and fan will turn on.
SENSITIVITY ADJUSTMENT
“SENSITIVITY”  has  been  factory  set  for  most 
shower applications. If the fan is in a tub area or is 
used for dampness control, the “SENSITIVITY” may 
need to be increased toward maximum (“MAX.”). 
If the control is responding too often to changing 
environmental conditions, adjustment toward less 
(“MIN.”) “SENSITIVITY” may be required. To adjust 
the “SENSITIVITY”:
1.  Turn power off at electrical service panel.
2.  Remove bulb.
3.  Through trim ring/baffle, locate the “SENSITIVITY” 
screwdriver slot.
4.  Using a small, flat-blade screwdriver, carefully 
rotate “SENSITIVITY”  adjustment  clockwise 
toward “MAX.” or  counterclockwise toward “MIN.”
5.  Re-install bulb.
6.  Turn power on and check operation by turning 
on shower or other humidity source until fan 
turns on.
7.  Repeat above steps if necessary.
TIMER ADJUSTMENT
This humidity-sensing fan has a “TIMER”. It is user-
adjustable from 5 to 60 minutes and is factory-set 
at 20 minutes. The “TIMER” controls how long the 
fan remains on (a) after rise in humidity and (b) 
humidity level are both below the user-adjustable 
“SENSITIVITY” setting or after being energized by 
cycling power switch.
To adjust the “TIMER”:
1.  Disconnect power at electrical service panel.
2.  Remove bulb.
3.  Through  the  trim  ring/baffle,  locate  the 
“TIMER” screwdriver slot.
4.  Using a small, flat-blade screwdriver, carefully 
rotate  “TIMER”  adjustment  clockwise 
to  increase  time  or  counterclockwise  to 
decrease time.
5.   Re-install bulb.
6.  Turn power on and check operation by cycling 
power switch as instructed under “MANUAL 
ON WITH TIMED OFF” or by turning on a 
humidity source until fan turns on.
7.  Check “TIMER” setting with watch or clock 
after  turning  humidity  source  off  if  it  was 
turned on it Step 6.
8. Repeat above steps if necessary.
CAUTION
  
1.   For  general  ventilating  use  only.  Do  not  use 
to  exhaust  hazardous  or  explosive  materials 
and vapors.
2.   To avoid motor bearing damage and noisy and/
or  unbalanced  impellers,  use  the  cardboard 
protector  (provided)  to  keep  drywall  spray, 
construction dust, etc. off power unit.
3.   The  fluorescent  bulb  used  with  this  product 
inserts  straight  into  the  bulb  socket. 
Do not 
attempt to insert or remove bulb by twisting it.
4.   Please read specification label on product for 
further information and requirements. 
WARNING    
TO  REDUCE THE  RISK  OF  FIRE,  ELECTRIC 
SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING:
1.   Use this unit only in the manner intended by the 
manufacturer. If you have questions, contact the 
manufacturer at the address or telephone number 
listed in the warranty.
2.   Before servicing or cleaning unit, switch power off 
at service panel and lock the service disconnecting 
means  to  prevent  power  from  being  switched 
on accidentally. When the service disconnecting 
means  cannot  be  locked,  securely  fasten  a 
prominent warning device, such as a tag, to the 
service panel.
3.   Installation work and electrical wiring must be done 
by a qualified person(s) in accordance with all 
applicable codes and standards, including fire-rated 
construction codes and standards.
4.   Sufficient  air  is  needed  for  proper  combustion 
and exhausting of gases through the flue (chimney) 
of fuel burning equipment to prevent backdrafting. 
Follow  the  heating  equipment  manufacturer’s 
guideline  and  safety  standards  such  as  those 
published by the National Fire Protection Association 
(NFPA), and the American Society for Heating, 
Refrigeration  and Air  Conditioning  Engineers 
(ASHRAE), and the local code authorities.
5.   When  cutting  or  drilling  into  wall  or  ceiling, 
do  not  damage  electrical  wiring  and  other 
hidden utilities.
6.   Ducted  fans  must  always  be  vented  to 
the outdoors.
7.   Never place a switch where it can be reached from 
a tub or shower.
8.   Do not use a dimmer switch to operate the light in 
this unit.
9.   Install this unit in a flat ceiling only.
10. For use in non fire rated installations only.
11.  Not for use in environmental air handling spaces.
12.  If this unit is to be installed over a tub or shower, it 
must be marked as appropriate for the application 
and be connected to a GFCI (Ground Fault Circuit 
Interrupter) - protected branch circuit.
13. Do not install in a ceiling thermally insulated to a 
value greater than R40.
14. This unit must be grounded.