American Standard 7837.024 Dépliant

Pagina di 1
L87
© 2008 AS America Inc.
BEDPAN CLEANSER ASSEMBLY
 
MODEL NUMBER:
7880.024 Bedpan Cleanser Assembly
Includes Component parts:
• 7866.015 Wall nozzle with hook
  • 7679.012 Double pedal valve 
  • 7544.018 Loose key wall supply
  • 7837.024 Atmospheric vacuum breaker
  • Self-closing handle
GENERAL DESCRIPTION:
Cast brass construction throughout. Single supply nozzle with 
built-in  wall  mounted  hook  for  spray  end.  4'  rubber  hose.  10" 
spray  end  with  self-closing  hand  valve  with  renewable  seats. 
Wall-mounted  self-closing  double  pedal  valve  with  renewable 
seats. Atmospheric vacuum breaker with top outlet to provide 
back flow protection. Wall-mounted supply with loose key stop.
PRODUCT FEATURES:
Brass  Construction: 
Durable  -  excellent  in  high  use 
applications.
Supply Nozzle: 
Cast brass with built-in hook to hold spray 
end.  Wall mounted.
Vacuum Breaker: 
Re-buildable back flow preventer. 
Cast  Aluminum  Foot  Action  Mixing: 
Water  supply 
controlled  by  self-closing  cast  aluminum  pedals  marked 
"hot"/"cold".
SUGGESTED SPECIFICATION
Bedpan Cleanser Assembly shall feature a wall mounted single inlet supply nozzle with built-in hook. Shall also feature wall 
mounted double pedal valve, vacuum breaker and wall supply with loose key stop. Cast brass construction throughout. Fitting 
shall be American Standard Model# 7880.024.002.
3/8 NPT
3/8 N.P.T. SUPPLIES
(NOT FURNISHED)
57mm
(2-1/4)
19mm
(3/4)
38mm
(1-1/2)
VACUUM BREAKER
32mm(1-1/4) DIA. HOLES 
IN WALL FOR 
1/2 N.P.T. SUPPLY
32mm(1-1/4) DIA. HOLES IN WALL FOR 
3/8 N.P.T. FOR INLET & OUTLET
ON VACUUM BREAKER
32mm(1-1/4) DIA. HOLES 
IN WALL FOR 
3/8 N.P.T. SUPPLY
76mm
(3)
32mm
(1-1/4)
CONCEALED PIPING
NOT FURNISHED
51mm
(2)
51mm
(2)
152mm
(6)
64mm
(2-1/2)
64mm
(2-1/2)
64mm
(2-1/2)
VACUUM BREAKER
SPRAY
60mm
(2-3/8)
102mm
(4)
OPTIONAL
TO FINISHED
FLOOR
352mm
(13-7/8)
371mm
(14-5/8)
APPROX.
35mm(1-3/8) MIN.
48mm(1-7/8) MAX.
OPTIONAL
OPTIONAL
83mm
(3-1/4)
89mm
(3-1/2) (4) HOLES
(FOR No. 14 F.H.W.S.)
FOR MOUNTING
PEDAL VALVE
FINISHED FLOOR
LINE
FINISHED WALL
LINE
PLUMBER NOTE- THIS DIMENSION
IS IMPORTANT AND 
MUST BE MAINTAINED