TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate both HANDLES (1) to flush water lines thoroughly.
Replace AERATOR (3).
5
2
3
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (5) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
11
“P” TRAP
WASTE
OUTLET
4
Loosen SET SEREW (1). Pull HANDLE (2) up to remove.
Remove ADAPTER SCREW (3) and pull off ADAPTER (4).
Remove SPRING CLIP (5).
Lift STOP WASHER (6), turn 90˚ and replace.
Replace SPRING CLIP (5).
Replace ADAPTER (4), ADAPTER
SCREW (3), HANDLE (2).
Tighten SET SEREW (1).
AERATOR (7) may accumulate dirt causing
distorted and reduced water flow.  Remove
AERATOR (7) and rinse clean.  
Turn VALVE to OFF position.
To change direction of handle rotation, proceed as follows:
10
SERVICE
1
M 9 6 8 4 6 8   R E V   1 . 2
90˚ 
7
If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90˚.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH  CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.