s
M968567 Rev.1.2
8
IS STOP VALVE OPEN?
LOOK FOR REPEATED
DOUBLE FLASH ON SENSOR
YES
INSTALL NEW BATTERY
TRY MANUAL VALVE BUTTON;
WILL THE UNIT FLUSH?
NO
REPLACE PISTON KIT
INSTALL NEW BATTERY
SEE STEP 10, page 6 in manual
NO
REPLACE SENSOR
NO
YES 
NO 
NO 
YES 
YES 
 
OPEN VALVE
UNIT WILL ONLY FLUSH MANUALLY
LOOK FOR REPEATED
DOUBLE FLASH ON SENSOR
RETRY AUTOMATIC FLUSH.
DOES THE UNIT FLUSH?
RETRY AUTOMATIC FLUSH.
TEST SENSOR. DISCONNECT
GRAY FLAT WIRE FROM BATTERY
COVER AND RE-CONNECT. SENSOR
SHOULD FLASH FOR 5 SECONDS.
DOES IT FLASH?
TEST SENSOR. DISCONNECT
GRAY FLAT WIRE FROM BATTERY
COVER AND RE-CONNECT. SENSOR
SHOULD FLASH FOR 5 SECONDS.
DOES IT FLASH?
CLOSE STOP VALVE,
REPLACE SOLENOID KIT.
RE-ASSEMBLE & INSTALL UNIT.
OPEN STOP VALVE.
BATTERY LOW;
REPLACE BATTERY
SEE STEP 10, page 6 in manual
NO 
NO 
YES 
DOES THE SENSOR FLASH
FOR THE FIRST 5 SECONDS?
NO
REPLACE SOLENOID KIT
RETRY AUTOMATIC FLUSH;
WAS IT SUCCESSFUL?
YES
1. COVER SENSOR FOR 10 SECONDS
2. UNCOVER SENSOR FOR 10 SECONDS.
REPLACE BATTERY
SEE STEP 10, page 6 in manual
MANUAL VALVE
OBSTRUCTED.
CLOSE STOP VALVE
AND SERVICE
RETRY AUTO FLUSH
NO
UNIT IS CONTINUOUSLY FLUSHING
PUSH MANUAL FLUSH
BUTTON; DOES IT RETURN?
LOOK FOR REPEATED
DOUBLE FLASH ON SENSOR
NO 
NO 
YES 
NO
1. COVER SENSOR FOR 10 SECONDS
2. UNCOVER SENSOR FOR 10 SECONDS.
   DOES THE UNIT STOP FLUSHING?
YES
INSTALL NEW BATTERY
SEE STEP 10, page 6 in manual
YES
1. CLOSE STOP VALVE,
2. REPLACE SOLENOID KIT.
3. RE-ASSEMBLE AND INSTALL UNIT.
4. OPEN STOP VALVE.
REPLACE SENSOR
NO
TROUBLESHOOTING FLOW CHARTS
UNIT DOES NOT FLUSH AT ALL
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
W
eekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA  1-800-387-0369   (TORONTO 1-905-306-1093)
W
eekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of AS America, Inc.
IN MEXICO  01-800-839-12-00
In
s
t
a
ll
a
t
io
n
 I
n
s
t
r
u
c
t
io
n
s