Locations to Avoid
• Do not install within 0.9 m (3') of the following: The
door to a kitchen, or a bathroom that contains a tub or
shower, forced air ducts used for heating or cooling,
ceiling or whole house ventilating fans, or other high
air-flow areas.  
• Do not place the alarm where drapes or other objects
will block the sensor.  Smoke must be able to reach the
sensor to accurately detect conditions. 
• Do not install in peaks of vaulted ceilings, “A” frame
ceilings or gabled roofs.  (Less than 10 cm (4") from the
peak of an “A” frame type ceiling.)
• Install at least 30.5 cm (12") away from fluorescent
lights as electronic noise may cause nuisance alarms.  
• Keep out of insect infested areas.  Avoid excessively
dusty, dirty or greasy areas.  Dust particles may cause
nuisance alarms or failure to alarm.
• Extreme temperatures may effect the sensitivity of the
alarm.  Do not install in areas where the temperature is
colder than 4.4°C (40°F) or hotter than 37.8°C (100°F).  
• Do not install in areas where the relative humidity (RH)
is greater than 85%. Very humid areas, with moisture or
steam, can cause nuisance alarms.
• Avoid placing ionization smoke alarms in kitchen areas.
Normal cooking may cause nuisance alarms.  If a
kitchen alarm is desired, it should have an alarm silence
feature or be a photoelectric type.
• Do not place in the garage.  Particles of combustion are
present when you start your automobile.
I n s t a l l a t i o n
I n s t a l l a t i o n
5
6
IMAGE 2A
IMAGE 2B
HORIZONTAL DISTANCE FROM PEAK
CEILING
10 cm (4”)
MINIMUM
SIDE WALL
BEST
PLACEMENT
ACCEPTABLE
PLACEMENT
NEVER HERE
10 cm (4”)
0.9 m (3’)
0.9 m (3’)
NOT IN
THIS AREA
BEST
ANYWHERE IN
THIS AREA
820-0612_RevA_1276_MAN_ENG  11/17/03  9:44 AM  Page 4