Chapter 2
Mounting
Topics covered in this chapter:
Mount the 9739 MVD transmitter to a wall
Prerequisites
• Use four 5/16-inch diameter (or M8) bolts and nuts that can withstand the process environment. Micro Motion does
not supply bolts or nuts (appropriate bolts and nuts are available as an option).
• Ensure that the surface is flat and rigid, does not vibrate, or move excessively.
Procedure
To minimize stress on the housing, secure all four mounting bolts to the same structure. Do not secure bolts to separate
girders, beams, or wall studs, which can move independently.
girders, beams, or wall studs, which can move independently.
4
Micro Motion 9739 MVD Transmitters