Sears 153.321342 Manuale Utente

Pagina di 32
7
The  lower  thermostat  is  factory  set  at  a  position  which 
approximates 120°F (49°C), and is adjustable if a different water 
temperature is desired. Read all warnings in this manual and on 
the water heating before proceeding.
FIGURE 27.
Temperature Settings
NOTE: Water temperature range of 120°—140°F (49°-60°C) 
recommended by most dishwasher manufacturers.
Temperature Setting
Time to Produce 2nd and 3rd
Degree burns on Adult Skin
160°F (71°C)
About 1/2 second
150°F (66°C)
About 1-1/2 seconds
140° (60°C)
Less than 5 seconds
130°F (54°C)
About 30 seconds
120°F (49°C)
More than 5 minutes
Upper and Lower Thermostat Adjustments
(Refer to thermostat illustrations under “Thermostats” section)
 
NOTE:  It  is  not  necessary  to  adjust  the  upper  thermostat. 
However, if it is adjusted above the factory set point of 120°F 
(49°C), it is recommended that it not be set higher than the lower 
thermostat setting.
Temperature Regulation
HOTTER  WATER  CAN  SCALD:  Water  heaters  are  intended 
to  produce  hot  water.  Water  heated  to  a  temperature  which 
will satisfy clothes washing, dish washing, and other sanitizing 
needs can scald and permanently injure you upon contact. Some 
people are more likely to be permanently injured by hot water 
than others. These include the elderly, children, the infirm, or 
physically/mentally handicapped. If anyone using hot water in 
your home fits into one of these groups or if there is a local code 
or state law requiring a certain temperature water at the hot water 
tap, then you must take special precautions. In addition to using 
the lowest possible temperature setting that satisfies your hot 
water needs, some type of tempering device, such as a mixing 
valve, should be used at the hot water taps used by these people 
or at the water heater. Mixing valves are available at plumbing 
supply or hardware stores. Follow manufacturers instructions for 
installation of the valves, before changing the factory setting of 
the thermostat see Temperature Settings table at right.
Never allow small children to use a hot water tap, or to draw 
their own bath water. Never leave a child or handicapped person 
unattended in a bathtub or shower.
Thermostats
The thermostats of this water heater have been factory set at 
a position which approximates 120°F (49°C), to reduce the risk 
of scald injury.
The  upper  thermostat  is  factory  set  at  a  position  which 
approximates 120°F (49°C), and is adjustable if a different water 
temperature is desired. Read all warnings in this manual and on 
the water heating before proceeding.
ADJUSTABLE UPPER THERMOSTAT
FIGURE 26.
SERVICE AND ADJUSTMENT