Thank You for purchasing a Maytag water heater. Properly
installed and maintained, it should give you years of trouble free
service. It is strongly suggested that this new water heater be
professionally installed, contact Maytag Customer Service (1-
800-788-8899) for recommended installers
.
Abbreviations Found In This Instruction Manual:
UL - Underwriters Laboratories Inc.
EPACT - Energy Policy Act
CAN - Canada
CSA - Canadian Standards Association
NFPA - National Fire Protection Association
ANSI - American National Standards Institute
ASME - American Society of Mechanical Engineers
GAMA - Gas Appliance Manufacturer’s Association
This gas-fired water heater is design certified by Underwriters
Laboratories Inc. under American National Standard/CSA
Standard for Gas Water Heaters ANSI Z21.10.3  • CSA 4.3
(current edition). The installation must conform with CAN/CSA -
B149.1, installation codes and/or Local Installation Codes.
•  Read the “Safety Precautions” section, page 3 of this manual
first and then the entire manual carefully. If you don’t follow
the safety rules, the water heater will not operate properly. It
could cause DEATH, SERIOUS BODILY INJURY AND/OR
PROPERTY DAMAGE.
This manual contains instructions for the installation, operation,
and maintenance of the gas-fired water heater. It also contains
warnings through out the manual that you must read and be
aware of. All warnings and all instructions are essential to the
proper operation of the water heater and your safety. Since
we cannot put everything on the first few pages, READ THE
ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR
OPERATE THE WATER HEATER.
The installation must conform with these instructions and local
code authority having jurisdiction. In the absence of local
codes, installations shall comply with the Natural Gas and
Propane Installation Code CAN/CSA - B149.1. This publication
is available from the Canadian Standards Association, 5060
Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W
5N6.
If after reading this manual you have any questions or do not
understand any portion of the instructions, call Maytag
Customer Service at 1-800-788-8899 for an authorized
servicer.
Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, and vent pipe
installation are very important in preventing death from
possible carbon monoxide poisoning and fires,  see
Figures 9 through 14.
Examine the location to ensure the water heater complies
with the Locating and Installing the New Water Heater
section in this manual.
CUSTOMER RESPONSIBILITIES
PRODUCT SPECIFICATIONS
TANK
RECOVERY
MINIMUM
DIMENSIONS
CAPACITY
TYPE
RATE GALS.
VENT PIPE
DIAMETER
 IN INCHES (mm)
IN GALS
OF
BTU
PER HOUR
INCHES
INCHES
 HEIGHT TOP OF
MODEL NUMBER
 (LTRS)
GAS
RATE
@ 90°F RISE
(mm)
(mm)
DRAFT HOOD
HRX75XQRSCGA
75 (284)
NATURAL
75,100
81.0
4” (102)
26 3/8” (670)
61 1/8” (1,553)
HRX75CQRSCGA
75 (284)
PROPANE
75,100
81.0
4” (102)
26 3/8” (670)
61 1/8” (1,553)
* Adding suffix “D” denotes high altitude (Example: HRX75XQRSCGAD). High altitude models have a B.TU./ Recovery Rate 10% less than shown.