Maytag C3 Manuale Utente

Pagina di 32
26
These guidelines should be used by a qualified Maytag Customer Service Center Agent. Call the Maytag Customer Service Center at
1-800-788-8899 for assistance. Inform the associate that this is a “Flammable Vapor Ignition Resistant” Product.
Problem
Cause
Solution
Improperly sealed, hot or cold supply connection,
Tighten threaded connections.
relief valve, drain valve, or thermostat threads.
Leakage from other appliances or water lines.
Inspect other appliances near water heater.
Condensation of flue products.
Refer to CONDENSATION.
Thermal  expansion  in  closed  water  system.
Install thermal expansion tank (DO NOT plug T&P valve).
Improperly seated valve.
Check relief valve for proper operation
(NO NOT plug T&P valve).
High sulfate or mineral content in water supply.
Drain and flush heater thoroughly, then refill.
Bacteria in water supply.
Chlorinate or aerate water supply.
Gas control knob not positioned correctly.
Refer to LIGHTING INSTRUCTIONS.
Main gas supply off.
Turn on main gas shutoff valve.
Igniter tip more than 1/8" from pilot hood.
Adjust igniter tip.
Thermocouple malfunction.
Replace pilot assembly.
Thermocouple TCO malfunction.
Replace pilot assembly.
Melted insulation on igniter wire or shorting
Contact a Maytag Customer Service Agent
PILOT WILL NOT LIGHT
of igniter wire.
 to determine cause.
High ambient room temperature.
Contact a Maytag Customer Service Agent
to determine cause.
Wire disconnected from spark igniter.
Reconnect wire connector to spark igniter.
Broken electrode or electrical wire.
Replace pilot assembly.
Piezo Igniter generator fails to operate or
Replace Piezo Igniter generator.
malfunctions.
Thermocouple TCO malfunction.
Replace pilot assembly.
High ambient room temperature.
Contact  a Maytag Customer Service Agent to
determine cause.
BURNER WILL NOT
Dirty or clogged air intake screen.
Clean and reinstall air intake screen.
STAY LIT
Flame arrestor openings blocked.
Contact a  Maytag Customer Service Agent to
determine cause.
Defective Gas Control.
Replace Gas Control.
Dirty pilot burner.
Clean pilot assembly.
Dirty or clogged air intake screen.
Clean and reinstall air intake screen.
Thermocouple tip is not in contact with pilot flame.
Insert  thermocouple  correctly.
Thermocouple malfunction.
Replace pilot assembly.
Thermocouple TCO malfunction.
Replace pilot assembly.
Defective Gas Control.
Replace Gas Control.
Heater not lit or thermostat not on.
Refer to LIGHTING INSTRUCTIONS.
Thermostat set too low.
Refer to TEMPERATURE REGULATION.
Heater undersized.
Reduce hot water use.
NOT ENOUGH
Low gas pressure.
Contact your gas supplier.
HOT WATER
Incoming water is unusually cold.
Allow more time for heater to re-heat.
Leaking hot water pipes or fixtures.
Have plumber check and repair leaks.
High temperature limit switch activated.
Contact a  Maytag Customer Service Agent to
determine cause.
WATER TOO HOT
Thermostat set too high.
Refer to TEMPERATURE REGULATION.
WATER HEATER SOUNDS
Condensation dripping on burner.
Refer to CONDENSATION.
Sediment or calcium in bottom of heater tank.
Clean sediment from tank.  Refer to DRAINING
instructions in Maintenance section of manual.
Improper combustion.
No adjustment available. Contact a  Maytag Customer
Service Agent
 
to determine cause.
Lack of supply air.
Improperly installed vent piping.
Contact a  Maytag Customer Service Agent to determine
Downdraft.
cause.
Poor combustion.
SIZZLING - RUMBLING
SOOTING
WATER LEAKS
LEAKING T&P VALVE
SMELLY ODORS
PILOT OUTAGE
VENT GAS ODORS
TROUBLESHOOTING GUIDE