insulation Blanket
Do not obstruct water heater air intake
with insulating blanket.
Gas and carbon monoxide detectors
are available.
Install water heater in accordance with
the instruction manual.
Breathing carbon monoxide can cause brain damage or
death. Always read and understand instruction manual.
Breathing Hazard - Carbon Monoxide Gas
Insulation blankets are available to the general public for external 
use  on  gas  water  heaters  but  are  not  necessary  with  these 
products. The purpose of an insulation blanket is to reduce the 
standby  heat  loss  encountered  with  storage  tank  heaters.  The 
water heaters covered by this manual meet or exceed the energy 
Policy Act standards with respect to insulation and standby heat 
loss requirements, making an insulation blanket unnecessary.
Should  you  choose  to  apply  an  insulation  blanket  to  this 
heater, you should follow these instructions. See the Features 
and  Components  section  of  this  manual  for  identification  of 
components mentioned below. Failure to follow these instructions 
can restrict the air flow required for proper combustion, potentially 
resulting in fire, asphyxiation, serious personal injury or death.
•  do not  apply  insulation  to  the  front  of  the  combustion 
chamber flange plate to insure that the spark igniter, flame 
sensor, and sightglass remain uncovered.
•  do not cover the gas valve or the Temperature-Pressure 
relief Valve.
•  do not apply insulation within 5” (13 cm) of the blower, to 
insure the safe operation of the blower assembly.
•  do not apply insulation on the control box that encloses 
the thermostat, ignition control, and variable frequency drive.
•  do not cover the instruction manual. Keep it on the side of 
the water heater or nearby for future reference.
•  do  obtain  new  warning  and  instruction  labels  from  the 
manufacturer for placement on the blanket directly over the 
existing labels.
•  do inspect the insulation blanket frequently to make certain 
it does not sag, thereby obstructing combustion air flow.
hard water
Where  hard  water  conditions  exist,  water  softening  or  the 
threshold  type  of  water  treatment  is  recommended.  This  will 
protect the dishwashers, coffee urns, water heaters, water piping 
and other equipment.
See the Maintenance Section in this manual for sediment and 
lime scale removal procedures.
CirCulation pumps
A circulating pump is used when a system requires a circulating 
loop or there is a storage tank used in conjunction with the water 
heater. See Water Piping Diagrams in this manual for installation 
location of circulating pumps.
See  the  Circulation  Pump  Wiring  Diagrams  (Figure  9.)  in  this 
manual for electrical hookup information. Install in accordance 
with the current edition of the national electrical Code, nFPA 70 
or the Canadian electrical Code, CSA C22.1.
All-bronze or stainless steel circulating pumps are recommended 
for use with commercial water heaters.
figure 7.
nsf leg kit
figure 8.
The nSF leg Kit (part number 9008214005) is needed only for 
applications  that  must  conform  to  nSF/AnSI  Standard  5.  The 
installed height of the water heater will increase by 3" (7.6 cm) when 
the leg kit is installed. Follow these steps to install the leg Kit. Use 
caution to prevent damage to the unit when installing the leg Kit
1.  lift, tilt or lay the unit on its side to access the bottom of the legs.
2.  Position the extension under leg aligning the holes in the leg 
extension with the holes in the leg. Assemble the bolt, bevel 
washers, flat washers, and nut through the aligned holes in 
the leg and leg extension as shown in Figure 8.
3.  Once in place, tighten the nut and bolt assembly. Torque to 70 
ft.lbs (9.67 kgf-m).
4.  Insure that all four nut and bolt assemblies are torqued to the 
specified value before placing the unit on the floor.