Elemental Designs eStat 761 Manuale Utente

Pagina di 3
eStat 761/762
      400-132-028-A                    11/6/07                    2/3
On the first installation, the screen displays: 0:00, MO,
and temperature (room/floor). 
For Floor Heating Installations: 
One of the two following messages may be displayed
when a problem occurs:
LO
: The floor temperature is below 0°C, or the 
temperature sensor is defective, or not connected. 
The heating indicator 
 is displayed and the relay is 
closed (energized).
HI
: The floor temperature is above 60°C, or the 
temperature sensor is defective.
n
Set the time (HOUR - MIN).
o
Set the day (DAY).
If you remove the module from its base for
more than 2 hours, the time and day will have
to be reprogrammed.
Comfort 
 
and Economy 
 
Setpoints
These setpoints are associated with the schedule’s programs (prog.
1 & 3 = Comfort, prog. 2 & 4 = Economy) and are preprogrammed as
follows:

eStat 761—
 28°C,   20°C

eStat 762—
 20°C,   18°C
To modify a setpoint:
n
Set the temperature using 
 and press and hold the 
 or 
 
button until it is displayed on the screen.
o
Press MODE/RETURN to exit.
Vacation Setpoint 
The vacation setpoint is associated to the Vacation operating mode
and is preprogrammed to 10°C. To modify this setpoint, repeat above
steps.
Floor Temperature Setpoint (eStat 762)
The floor temperature limit is preprogrammed to 28°C to avoid dam-
age to your floor. 
To modify, press the adjustment button (below
) using a pointed
object, set the desired temperature using 
 and  press MODE/
RETURN to exit.
The eStat thermostat offers three operating modes:
Automatic
Executes the schedule.
 
n
Press MODE to select 
. The current 
program number is displayed.
You can temporarily bypass the current program by
setting a specific temperature setpoint 
 or by
selecting one of the pre-defined setpoint buttons
(
). The new setpoint will be maintained until the
beginning of the next program.
Manual 
—Maintains a constant temperature.
n
Press MODE to select  
.
o
Set temperature 
 or select one of the pre-defined 
setpoint buttons (
).
Vacation
—Maintains the Vacation setpoint during a 
prolonged absence. 

Press .
The schedule is used with the Automatic mode. The schedule con-
trols the heating system to automatically switch between the Comfort
and Economy temperature setpoints at the times you have pro-
grammed. 
The schedule consists of 4 programs per day defined as follows:
To enter the programs’ start time
To shorten programming, you simply have to enter the start time for
each program.
n
Press PGM.
o
Press DAY to select the day (hold for 3 seconds to select all 
days of the week).
Note:
It is sometimes faster to program the same schedule for the
entire week and then to modify the exception days.
p
Press PGM to select the program number (e.g. 1).
q
Press HOUR and MIN to set the start time.
r
Repeat steps 3 to 4 for remaining programs (e.g. 2, 3 and 4).
s
Press MODE/RETURN to exit.
Note:
After 60 seconds of inactivity, the thermostat will automatically
exit programming mode. 
r
Power Up
4.
s
Set the Time and Day
5.
t
Adjust the Temperature Setpoints
6.
u
Select the Operating Mode
7.
v
Program Your Schedule
8.
Programs
Setpoint
Time
a
a.
The programs’ start time can be different for each day of the week.
Wake-up
Leave home
Back home
Night
400-132-028-A (CJ Electric Elements TH132 F_AF 15-min eStat 761_762) ENG.fm  Page 2  Monday, June 11, 2007  4:26 PM