When facing the front of the appliance the following 
minimum clearances to combustible construction must be 
maintained.
Left side 8 inches (203mm). Right side 8 inches 
(203mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Minimum vertical clearance from a projection above 
the appliance (shelves, window sills, etc.) 36 inches 
(914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches 
(51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing 
and proper operation must be provided.
Refer to Figures 9, 10, 11 and 12 for measurements in order to locate (4) mounting holes on wall. Figures 9, 10, 11 and 12 are the front 
views of the heaters.
1. Remove lower louver from casing assembly (2 screws).
2. Remove reflector from casing assembly (2 screws).
3. Remove upper louver from casing assembly (2 screws).
SR-30 CLEARANCES
WALL MOUNT INSTALLATION