CLEARANCES
CLEARANCES TO COMBUSTIBLES
 (both sides) 
MANTEL CLEARANCES 
NOTE: The combustible area above the facing must not protrude more than 
3
/
4
" from the facing. If it does, it is 
considered a mantel and must meet the mantel requirements listed in this manual. 
Figure 6 - Clearances 
Follow these instructions carefully to ensure safe installation. Failure to follow instructions 
exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other 
than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed 
on a metal, wood or non-combustible material panel extending full width and depth of 
the appliance.
WARNING
Clearance to 
Combustibles
 
Sides 
0
 
Floor 
0
 
Back 
0.5"
 
Standoff 
0"
 
Front 
36" 
The fireplace face must be
completely covered with
any non-combustible ma-
terial. Allow clearance for
removal of front air panel