TROUBLE SHOOTING 
 
 
PROBLEM SOLUTION 
Hair and lint pot cover is tight and o-ring is in place 
and free from defects. 
Valves on suction and return lines are working 
properly and open. 
Water level in pool is too low. 
Filter o-ring or gasket is in place and free from 
defects. 
If pump loses prime, 
or if too many bubbles 
come through return 
line, check: 
 
All fittings and connections are secure and air tight. 
Filter pressure gauge reading too high, indicating filter 
needs cleaning. 
Clogged plumbing lines. 
Impeller adjustment incorrect.  Adjust impeller .015 
inches from face of volute. 
Not pumping water, 
check: 
Worn or damaged impeller. 
Circuit breakers. 
Incorrect or loose wire connections. 
 
Motor does not run, 
check: 
 
 Thermal protector in motor tripped.  Allow motor to 
cool, then try to restart. 
Make sure motor shaft turns free. 
Jammed impeller or an obstruction in (volute) casing. 
Motor makes 
humming noise but 
won’t start, check: 
Low voltage and undersized wire. 
Incorrect or loose wire connections. 
Low voltage supply (frequently caused by undersized 
wire. 
Motor overheating and 
cycling on and off, 
check: 
Make sure the motor gets a fresh air supply and the 
vents are kept unclogged. 
 Plumbing vibration 
Impeller turns freely and is properly adjusted. 
Motor bearings. 
Noises, check: 
For cavitation, due to obstruction in or undersized 
suction line.