Multiquip LS600P Manuale Utente

Pagina di 88
MaYCO LS600p CONCReTe pUMp • OpeRaTiON MaNUaL — Rev. #0 (05/13/13) — page 33
OPERAtIOn
Starting Procedure
1.  Locate the 
emergency stop switch (Figure 20) on 
the 
digital control panel. Turn the emergency stop 
switch clockwise and release (open). This will allow 
the engine to start.
Figure 20. Emergency Stop Switch
2.  Place the 
cylinder stroke control switch in the 
aUTOMaTiC position (Figure 21).
Figure 21. Cylinder Stroke Control Switch 
(Automatic)
3.  Place the 
pumping control switch in the CENTER 
OFF position (Figure 22) for normal pumping operation.
Figure 22. Pumping Control Switch (OFF)
  WaRNiNg
DO NOT attempt to operate this concrete pump until 
the Safety, General Information and Inspection sections 
have been read and understood.
 
E
m
erg
ency S
top
 NOTICE
If the 
emergency stop switch is in the closed position 
(
STOP), engine will not start. To start the engine, make 
sure the emergency stop switch is in the 
OPEN position 
(fully extended).
AUTOMATIC
JOG
LOCAL
REMOTE
CENTER
OFF
4.  Place the 
direction control switch to the FORWARD 
position (Figure 23).
Figure 23. Direction Control Switch 
(FORWARD)
5.  To start the engine, insert the ignition key (Figure 24) 
into the ignition switch and turn the key to the 
ON 
position.
Figure 24. Ignition Switch
6.  When the ignition key is in the 
ON position, the digital 
readout screen (primary) will cycle through 3 displays 
as shown in Figure 25.
Figure 25. Primary Screen (Ignition Key ON)
7.  Turn the key to the 
START position and listen for the 
engine to start. In warm weather let engine warm up 
for 5 minutes. In cold weather, let engine warm up for 
10 minutes.
FORWARD
REVERSE
IGNITION
ON
OFF
START
LS  600  OFF
0000 ENG RPM
BATTERY 12.5 V
LOW OIL PSI
1
LS 600  OFF
0000 ENG RPM
BATTERY 12.5 V
LOW RPM FAULT
1
LS  600  OFF
0000 ENG RPM
BATTERY 12.5 V
END OF MESSAGE