About Connectors
38
*The error output timing is set under [Basic] on the settings menu (refer to the Setup Instructions (PDF file)).
Note:
•
During L active (Low active), the logic is enabled when the signal's voltage level is Low.
•
During H active (High active), the logic is enabled when the signal's voltage level is High.
Alarm/Control connector and Alarm Connector Timing and Polarity
Connectors
Active Time
Remarks
Alarm input
100 ms or more
L active
Alarm output
The time set on the setup menu
L active
Network error output
Until the network error is cleared, or until the [ERR] button on
the operation window (browser) is clicked.
the operation window (browser) is clicked.
L active
Alarm reset input
100 ms or more
L active
Emergency recording input
100 ms or more
L active
Available disk space warning output
From the time of the error occurrence until the time of the
error output duration
error output duration
*
L active
HDD error output
From the time of the error occurrence until the time of the
error output duration
error output duration
*
L active
Camera error output
From the time of the error occurrence until the time of the
error output duration or the camera is reset
error output duration or the camera is reset
*
L active
Error output
From the time of the error occurrence until the time of the
error output duration
error output duration
*
L active
Time adjustment input/output
Input: 100 ms or more
Output: 1 s
Output: 1 s
Input/Output:
L active
L active
Alarm suspension input
100 ms or more
L active, judged level
External recording mode switching
100 ms or more
L active
Outage detection input
5 s or more
L active
Power outage recovery completion
output
output
10 s or more
H active