WARNING
 EXCESSIVE AIR PRESSURE. Can cause per-
sonal injury, pump damage or property damage.
Do not exceed the maximum inlet air pressure as 
stated on the pump model plate.
Be sure material hoses and other components are able 
to withstand fluid pressures developed by this pump. 
Check all hoses for damage or wear. Be certain dispens-
ing device is clean and in proper working condition.
WARNING
 STATIC SPARK. Can cause explosion re-
sulting in severe injury or death. Ground pump and 
pumping system.
Use the pump grounding screw terminal provided. 
Use ARO® part no. 66885-1 ground kit or connect a 
suitable ground wire (12 ga. min.) to a good earth 
ground source.
The pumping system and object being sprayed must be 
grounded when it is pumping, flushing, recirculating or 
spraying flammable materials such as paints, solvents, 
lacquers, etc. or used in a location where surrounding 
atmosphere is conducive to spontaneous combustion. 
Ground the dispensing valve or device, containers, hos-
es and any object to which material is being pumped.
Secure pump, connections and all contact points to 
avoid vibration and generation of contact or static spark.
Consult local building codes and electrical codes for 
specific grounding requirements.
After grounding, periodically verify continuity of 
electrical path to ground. Test with an ohmmeter 
from each component (e.g., hoses, pump, clamps, con-
tainer, spray gun, etc.) to ground to insure continuity. 
Ohmmeter should show 0.1 ohms or less.
Submerse the outlet hose end, dispensing valve or 
device in the material being dispensed if possible. 
(Avoid free streaming of material being dispensed.)
Use hoses incorporating a static wire.
Use proper ventilation.
Keep inflammables away from heat, open flames and sparks.
Keep containers closed when not in use.
WARNING
 Pump exhaust may contain contaminants. 
Can cause severe injury. Pipe exhaust away from work 
area and personnel.
In the event of a diaphragm rupture, material can be 
forced out of the air exhaust muffler.
Pipe the exhaust to a safe remote location when 
pumping hazardous or inflammable materials.
Use a grounded 1” minimum i.d. hose between the 
pump and the muffler.
WARNING
 HAZARDOUS PRESSURE. Can result in se-
rious injury or property damage. Do not service or 
clean pump, hoses or dispensing valve while the sys-
tem is pressurized.
Disconnect air supply line and relieve pressure from 
the system by opening dispensing valve or device and 
/ or carefully and slowly loosening and removing out-
let hose or piping from pump.
WARNING
 HAZARDOUS MATERIALS. Can cause serious 
injury or property damage. Do not attempt to return 
a pump to the factory or service center that contains 
OPERATING AND SAFETY PRECAUTIONS
READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.
hazardous material. Safe handling practices must 
comply with local and national laws and safety code 
requirements.
Obtain Material Safety Data Sheets on all materials 
from the supplier for proper handling instructions.
WARNING
 EXPLOSION HAZARD. Models containing 
aluminum parts cannot be used with 1,1,1-trichlo-
roethane, methylene chloride or other halogenated 
hydrocarbon solvents which may react and explode.
Check pump motor section, fluid caps, manifolds and 
all wetted parts to assure compatibility before using 
with solvents of this type.
WARNING
 MISAPPLICATION HAZARD. Do not use 
models containing aluminum wetted parts with food 
products for human consumption. Plated parts can 
contain trace amounts of lead.
CAUTION
 Verify the chemical compatibility of the 
pump wetted parts and the substance being pumped, 
flushed or recirculated. Chemical compatibility may 
change with temperature and concentration of the 
chemical(s) within the substances being pumped, 
flushed or circulated. For specific fluid compatibility, 
consult the chemical manufacturer.
CAUTION
 Maximum temperatures are based on 
mechanical stress only. Certain chemicals will signifi-
cantly reduce maximum safe operating temperature. 
Consult the chemical manufacturer for chemical com-
patibility and temperature limits. Refer to PUMP DATA 
on page 1 of this manual.
CAUTION
 Be certain all operators of this equipment 
have been trained for safe working practices, under-
stand it’s limitations, and wear safety goggles / equip-
ment when required.
CAUTION
 Do not use the pump for the structural sup-
port of the piping system. Be certain the system com-
ponents are properly supported to prevent stress on 
the pump parts.+++Suction and discharge connections 
should be flexible connections (such as hose), not rigid 
piped, and should be compatible with the substance 
being pumped.
CAUTION
 Prevent unnecessary damage to the pump. 
Do not allow pump to operate when out of material 
for long periods of time.
Disconnect air line from pump when system sits idle 
for long periods of time.
CAUTION
 Use only genuine ARO replacement parts to 
assure compatible pressure rating and longest service 
life.
NOTICE
 Replacement warning labels are available 
upon request: “Static Spark & Diaphragm Rupture” pn \ 
94080.
WARNING
  = Hazards or unsafe practices which 
could result in severe personal injury, 
death or substantial property damage.
CAUTION
  = Hazards or unsafe practices which 
could result in minor personal injury, 
product or property damage.
NOTICE
  = Important installation, operation or 
maintenance information.
EXCESSIVE AIR PRESSURE
STATIC SPARK
HAZARDOUS MATERIALS
HAZARDOUS PRESSURE