Tag and disconnect the three tubing connections on the desalinator namely the feed, 
concentrate and product. 
 
• 
Unsnap the desalinator retainers and pull desalinator(s) out. 
 
• 
Remove retaining clips from ends of desalinator by tapping the open ends of the clips with 
a plastic or rawhide mallet until they are through the slots in the pressure vessel.   Pull 
clips completely out of pressure vessel. 
 
• 
Remove end plugs by gently pulling on the fittings.  Do not use pliers on the fitting threads 
because the threads might get damaged.  As a suggestion, attach a scrap piece of tubing 
(with a nut, a ferrule and an insert), and then use the tubing as a handle.  See §8.0 
PARTS & ACCESSORIES for end plug pulling tool. 
 
• 
Push membrane out of pressure vessel from the feed end. 
 
• 
Discard old membrane.  Be careful not to discard the gray closed-end plug or the product 
inter-connector. 
 
• 
Clean vessel and plugs with a mild detergent soap and rinse thoroughly. 
 
• 
Inspect all O-rings for cracks or nicks, replace as necessary.  Lubricate O-rings with an 
appropriate petroleum or silicone-based lubricant. 
 
• 
Install new membrane into the feed end of vessel (in the direction shown in Figure 4).  Be 
sure to note the end with the brine seal. 
 
• 
Install closed-end plug into vessel feed end plug, and product inter-connector into the 
vessel concentrate/product end plug. 
 
• 
Install end plugs into their proper ends.  IF END PLUGS ARE INSTALLED ON THE 
WRONG ENDS THE SYSTEM WILL NOT OPERATE PROPERLY. 
 
• 
Install retaining clips and mount desalinator onto frame using tabs and install the retaining 
clips. 
 
• 
Connect feed, concentrate, and product lines to their proper ports.