StorageTek 6 Manuale Utente

Pagina di 718
Appendix D. Logging ACS Robotics Motion   607
1st ed., 6/30/04 - 312579601
 
The HSC also makes a log entry for each permanent error, codes and indicates whether or 
not the errors are considered permanent errors. 
The record format used to log a hard fail to SYS1.LOGREC is shown in Table 68. This 
record is a valid ‘‘Motion Hard Fail Software Error Record’’ only under the following 
conditions: 
• if the Record Type Field (bytes 642-643) has a value of X’6501’, 
• the StorageTek identifier (X’FEEDFACE’ at bytes 644-647) is present, and 
• the character ‘H’ appears at the byte 113 location. 
124-127
LSM 9 Temporary motion error counts (binary) 
128-131
LSM 10 Robotic motions started (binary) 
132-135
LSM 10 Temporary motion error counts (binary) 
136-139
LSM 11 Robotic motions started (binary) 
140-143
LSM 11 Temporary motion error counts (binary) 
144-147
LSM 12 Robotic motions started (binary) 
148-151
LSM 12 Temporary motion error counts (binary)  
152-155
LSM 13 Robotic motions started (binary)
156-159
LSM 13 Temporary motion error counts (binary)
160-163
LSM 14 Robotic motions started (binary)
164-167
LSM 14 Temporary motion error counts (binary)
168-171
LSM 15 Robotic motions started (binary)
172-175
LSM 15 Temporary motion error counts (binary)
176-641
Reserved
642-643
Record type X’6506’
644-647
StorageTek identifier X’FEEDFACE’
648-651
Timestamp Table
Table 67.  Format for Total Motions and Temporary Error Counts (Continued)
Initiated and Temporary Error Motion Software Error Record
BYTE #
Description of Field