StorageTek 6 Manuale Utente
Appendix D. Logging ACS Robotics Motion 607
1st ed., 6/30/04 - 312579601
The HSC also makes a log entry for each permanent error, codes and indicates whether or
not the errors are considered permanent errors.
not the errors are considered permanent errors.
The record format used to log a hard fail to SYS1.LOGREC is shown in Table 68. This
record is a valid ‘‘Motion Hard Fail Software Error Record’’ only under the following
conditions:
record is a valid ‘‘Motion Hard Fail Software Error Record’’ only under the following
conditions:
• if the Record Type Field (bytes 642-643) has a value of X’6501’,
• the StorageTek identifier (X’FEEDFACE’ at bytes 644-647) is present, and
• the character ‘H’ appears at the byte 113 location.
• the StorageTek identifier (X’FEEDFACE’ at bytes 644-647) is present, and
• the character ‘H’ appears at the byte 113 location.
124-127
LSM 9 Temporary motion error counts (binary)
128-131
LSM 10 Robotic motions started (binary)
132-135
LSM 10 Temporary motion error counts (binary)
136-139
LSM 11 Robotic motions started (binary)
140-143
LSM 11 Temporary motion error counts (binary)
144-147
LSM 12 Robotic motions started (binary)
148-151
LSM 12 Temporary motion error counts (binary)
152-155
LSM 13 Robotic motions started (binary)
156-159
LSM 13 Temporary motion error counts (binary)
160-163
LSM 14 Robotic motions started (binary)
164-167
LSM 14 Temporary motion error counts (binary)
168-171
LSM 15 Robotic motions started (binary)
172-175
LSM 15 Temporary motion error counts (binary)
176-641
Reserved
642-643
Record type X’6506’
644-647
StorageTek identifier X’FEEDFACE’
648-651
Timestamp Table
Table 67. Format for Total Motions and Temporary Error Counts (Continued)
Initiated and Temporary Error Motion Software Error Record
BYTE #
Description of Field