Russound CA4 Manuale Utente

Pagina di 32
17
Russound CA4 System Installation  Manual
Triggers
12VDC Mute Trigger In
When 12VDC is applied to the Mute In, the system will fully mute all zones on 
the controller. The connections for the trigger are made using a two-conductor 
cable  with  1/8"  male  mini-plug  jacks.  The  tip  is  positive  (+)  and  sleeve  is 
negative  (-). This  allows  for  the  connection  of  an  external  paging  or  muting 
device. In a dual controller configuration a mini plug Y cable should be used to 
send the signal into both Mute In jacks so all zones will be muted. 
Note: The CA4 will not accept a paging audio input; however, if used with 
an independent paging system with 12VDC trigger out, that can be used to 
trigger the mute. 
12VDC System Trigger Out
Trigger Out 12VDC output is used for triggering an external amplifier or other 
component. The connections for the output are made using a two-conductor 
cable with 1/8" male mini-plug jacks at each end. The tip is positive (+) and 
sleeve is negative (-). The System Trigger Out supplies 12VDC when the first 
keypad is turned on. The 12VDC is removed 5 minutes after the last keypad is 
turned off. 
Sample Trigger Connections
CONTROLLER CONNECTIONS