Antares TA-1VP Manuale Utente

Pagina di 44
30
  
TASCAM TA-1VP
Compressor Knee Page
 
ª
Pressing the KNEE button brings up this page:
Compressor Knee:  40 
  (0 is hard)
The Knee control adjusts the sharpness of the transitions 
between uncompressed and compressed signals. As 
a signal increases in level through the threshold, the 
compressor will begin to apply gain reduction. With a 
soft knee (100), that change in gain will be gradual and 
therefore less noticeable.
The range of the control is from 0 (hard knee) to 100 (soft 
knee). (The default setting is 48.)
Gate Page
 
ª
Pressing the GATE button brings up this page:
Th:-36dB_____|
Gate Ratio:  1:20
This page allows you to set the main Gate parameters. 
Use the cursor buttons to move from field to field and the 
Data Knob to set each parameter. For ease in setting the 
threshold, this page includes a display of the incoming 
signal level and a graphic indication of the currently 
selected threshold. The threshold should be set just above 
the level of the signal that you wish to gate.
Pressing the GATE button again while the Gate Page is 
displayed will display the Gain Reduction Meter Page 
(see below). Continually pressing the GATE button will 
alternate between the two pages.
The ranges of the parameters are as follows: 
Threshold: –90 dB (default setting) - 0 dB
Ratio: 1:1.0 (default setting) - 1:99
Gain Reduction Meter Page
 
ª
C/G:-20 -12 -6 -3  0
         ¡¡¡¡¡¡¡¡¡¡¡
Pressing either the COMP or GATE buttons while their 
respective pages are displayed will display this high 
resolution gain reduction meter. The meter displays the 
amount of gain reduction applied to the signal. When the 
input signal is above the compression threshold or below 
the gate threshold, the gain reduction meter will display 
the amount of compression or gating being applied. 
Pressing the COMP or GATE button again will return to 
the appropriate page.
Gain Reduction Meter
 
ª
The front panel GAIN REDUCTION meter is intended 
to provide a quick indication of compressor and gate 
activity. For precise gain reduction indication, refer to the 
Gain Reduction Meter Page described above. The range of 
the meter is 15 dB.
COMPRESSOR/GATE ON Button
 
ª
When this button is lit, the COMPRESSOR/GATE module 
is active. When it is not lit, the module is bypassed. 
Pressing the button toggles its state. The Comp/ Gate On/
Off function can also be controlled by MIDI and/or by a 
footswitch.
DE-ESSER MODULE
De-esser Page
 
ª
Pressing the DE-ESS button brings up this page:
This page allows you to set the main de-esser parameters. 
Use the cursor buttons to move from field to field and the 
Data Knob to set each parameter. For ease in setting the 
threshold, this page includes a display of the incoming 
high-pass signal level and a graphic indication of the 
currently selected threshold. The threshold must be set 
below the signal peaks for any de-essing to occur.
Pressing the DE-ESS button again while the De-esser 
Page is displayed will display the De-esser Gain Reduction 
Meter Page (see below). Continually pressing the DE-ESS 
button will alternate between the two pages.
The ranges of the parameters are as follows: 
Threshold: –60 dB - 0 dB (default setting)
Ratio: 1.0:1 - 99:1
NOTE
If you are using the Double Track function (see below), the 
de-esser works on both the main and the double track.
De-esser Attack Page
 
ª
Pressing the ATK button brings up this page:
   De-esser Attack
       15 ms
The Attack Time control adjusts the speed with which the 
de-esser’s compressor element responds to peaks in the 
signal coming from the highpass filter. The range of the 
control is from 0 milliseconds to 200 milliseconds. (The 
default setting is 15 milliseconds.)
De-esser Release Page
 
ª
Pressing the REL button brings up this page:
5 – Operation