d.  Room Measurements 
 
 
The  number  of  room  positions  needed  depends  on  the  value  of  RoomKnowledge,  if  it  is 
below  90%  after  the  third  measurement  the  guide  automatically  includes  extra  room 
measurements until a RoomKnowledge of 90% or more has been achieved. 
 
The  remaining  measurements  are  to  be  placed  in  random  positions  in  the  room  with 
random orientations of the microphone. Choosing these random or arbitrary positions and 
orientations is easy. All you have to do is place the microphone at different positions in the 
room and with different orientations. It is important to perform well spaced measurements 
to  get  a  covering  image  of  the  acoustical  properties  in  the  room,  i.e.  varying  positions, 
heights and orientations of the microphone. 
 
For an optimal room correction it is very important that the measurements are:  
1.  performed more than 1 meter (approx. 3 feet) away from the loudspeakers,  
2.  not performed behind the loudspeaker, and  
3.  that there is at least 50 cm (approx. 1.5 feet) between each measurement. 
 
These points are illustrated in figure 4. 
 
 
 
Fig 4: Illustration of guidelines for room measurements  
 
 
When  a  random  measuring  position  and  microphone  orientation  has  been  chosen  press 
enter.  The  measuring  process  will  start  and  the  display  will  show  the  following  while 
measuring. 
 
 
 
The measurement will stop prematurely if an error occurs during the measuring process. In 
this case, the error message is displayed. Press enter to continue.