Pass Labs X5 Manuale Utente
7
X5 Owner’s Manual
All figures obtained after a 1 hour warmup, with regulated 120 VAC
power line. See manual notes about AC power line regulation.
power line. See manual notes about AC power line regulation.
Gain
30 dB
Freq. Response
-0 dB at DC, -3 dB at 100 kHz
Power Output
125 X 5 watts maximum @ 1% THD,
1 kHz, 8 ohms
Maximum Output Voltage
plus, minus 50 volts
Maximum Output Current
plus, minus 10 amps
Input Impedance
22 kohm balanced
Damping factor
200 ref 8 ohms nominal
Slew rate
plus, minus 50 V/uS
Output Noise
300 uV unweighted 20-20 kHz
Balanced CMRR
-85 dB @ 1 kHz (input common
mode rejection ratio)
DC offset
< 100 mv
Power Consumption
200 watts idle, 600 watts maximum
Temperature
20 degrees C. above ambient typical
Dimensions
19 “ W x 7” H x 20” D
Shipping Weight
74 lbs.
For more information please contact:
Pass Laboratories Inc.
P.O. Box 219,
24449 Foresthill Rd.,
Foresthill, CA 95631
24449 Foresthill Rd.,
Foresthill, CA 95631
Tel: 530.367.3690
Fax: 530.369.2193
Fax: 530.369.2193
www.passlabs.com
© 2006, Pass Laboratories Inc.
X5 Specifications
“Pass”, “pass”, “Pass Labs”, “Pass Laboratories”, Supersymmetery”,
“Aleph”, and “Zen” and are all registered trademarks of Pass
Laboratories, Inc., and all rights thereto are protected by law.
“Aleph”, and “Zen” and are all registered trademarks of Pass
Laboratories, Inc., and all rights thereto are protected by law.