Step 1: Selecting Speaker Location
One CNXQ™ Flat Panel Ceiling Speaker is  designed 
for rooms smaller than 1200 sq. ft. and with a ceiling 
height of 9–12 feet.
Before starting the system installation, speaker placement 
needs to be determined. This speaker is designed to 
be mounted in the ceiling in or near the middle of the 
classroom (See figure 1.). The speaker lays directly into the 
acoustic ceiling grid, so locate the tile that is approximately 
in the center of the classroom.
Step 2: Installing and Connecting the Speaker Wire
A.  Identify a suitable location for the receiver/amplifier 
 
where it is easily assessable, close to a power outlet,  
 
and at least 6 feet away from any computers.
B.  Remove the ceiling tile from the ceiling that was  
 
identified in Step 1.
C.   Set the ceiling tile on a flat work surface with patterned 
 
side facing down. The dimensions of the CNXQ Speaker 
 
are 2’ x 2’ Using a straight edge, cut 24” off the 
 
end of a standard  2’ x 4’ ceiling tile as shown in Figure 
 
2.  (If the ceiling tile grid is 2’ x 2’, simply remove the 
 
tile and replace with the CNXQ speaker).
D.   Locate the coil of speaker wire. To connect the wire to 
 
the speaker, press down on the colored terminals on 
 
the back of the speaker, insert the wire and release 
 
the tab to clamp it in place. Insert the black wire into 
 
the black-tabbed terminal and the red wire into the  
 
red-tabbed terminal.
E.   Place the other end of the wire up through the opening 
 
in the ceiling and route over the ceiling tiles and back 
 
down the wall to the receiver/amplifier. (NOTE: when 
 
routing wire overhead, it is important to always follow 
 
local building and electrical codes, securing wire as 
 
required). Do not connect the wires to the receiver 
 
amplifier yet.
F. 
If installing the speaker into a 2’ x 4’  suspended  
 
ceiling, snap the included cross tee into the suspended 
 
ceiling grid. Locate the slots in the grid at the center of 
 
the 2’ x 4’ area. Insert one end of the tee, then the 
 
other so it locks into place.
G.   The speaker has an earthquake strap connected to the 
 
back so it can be tied off to the ceiling structure for 
 
safety purposes. Unscrew one end of the wire from the 
 
back of the speaker to be tied off to the ceiling  
 
supports. If local building codes do not require the use 
 
of an earthquake strap and it is not being used, you 
 
should completely remove the strap from the speaker 
 
so that does not create unwanted vibration.
H.   Lay the CNXQ directly onto the ceiling tile grid as 
 
shown in Figure 3. Secure the speaker to the ceiling 
 
with the earthquake strap as required by local  building 
 
codes. Speaker wire should also be secured to the  
 
ceiling. DO NOT lay the speaker wire across the back 
 
of the speaker to avoid unwanted vibration.
I. 
Insert the cut tile back into the ceiling.
LightSPEED
CNXQ™ Flat-Panel Ceiling Speaker Installation 
Instructions for the 820/850/880iR Receiver/Amplifier
Start your system installation with the 
“System Installation” section of the User Manual
All LightSPEED speakers should be in 
accordance with Uniform Building Code, state 
and local building department requirements
Room Installation: Top View
CNXQ
Figure 1:
Cutting a 2’ x 4’ Ceiling Tile
Throw
Away
Remaining
Ceiling Tile
Installing the Speaker
Ceiling Tile Grid
CNXQ Speaker
Cross Tee
Ceiling Tile
Figure 2:
Figure 3:
24”
Cut with Straight Edge