ACHERON OPERATING INSTRUCTIONS
31
Reset Button
Pressing the Reset button causes the RMS module’s firm-
ware to reboot; this will not affect whether the loudspeaker 
is commissioned (which is stored in flash memory). You can 
simultaneously press the Reset and Service buttons to reset 
the RMS module and decommission the loudspeaker from 
the network (see “Resetting the RMS Module” on page 31).
Activity LED (Green)
The green Activity LED flashes continuously when the loud-
speaker has been successfully commissioned. 
Network Connectors
The two Weidmuller connectors transfer data to and from 
the RMS network. Two connectors are provided to allow for 
easy connection of multiple (daisy-chained) loudspeakers 
on the network. Included with each RMS-equipped loud-
speaker are RMS cable connectors and mounting blocks for 
constructing RMS cables. The RMS blocks allow the cables 
to be securely attached to the RMS module with screws.
RESETTING THE RMS MODULE
You can use the Reset and Service buttons to reset the RMS 
module, which will cause the module to be decommissioned 
from the network.
To reset the RMS module:
1. Press and hold the Service button for 10 seconds.
2. While continuing to hold down the Service button, press 
and hold the Reset button for 5 seconds.
3. After releasing the Reset button, continue holding down 
the Service button for 5 seconds. The RMS module is 
reset and the loudspeaker is decommissioned. The RMS 
module’s red Service LED blinks.