Nady Systems GEQ131 Manuale Utente

Pagina di 10
6
7. IEC Power Cord Receptacle 
This.is.used.to.connect.the.AC.power.source.to.your.equalizer..
Power requirements: 115VAC, 60Hz 
CAUTION: For new installations and portable sound systems, 
or in any situation in which the AC power is suspect, it is wise to 
confirm appropriate voltage and line polarity BEFORE connecting 
the instrument to the power source.
8. Fuse Holder 
This.fuse.holder.contains.an.AC.primary.fuse..This.fuse.should.be.
replaced.with.the.same.type.fuse.when.this.is.blown.out..If.they.
continuously.blow,.stop.replacing.the.fuse.and.refer.servicing.to.
qualified.personnel..
CAUTION: After checking the AC supply voltage, be sure that the 
correct fuse is in the fuse holder. A 20mm glass tube 500mA 250V 
fast-blow fuse should be used. 
9. Input/Output Connectors 
Balanced.XLR.and.1/4”.TRS.Inputs.and.unbalanced.output.jacks.
for.line.level.operation..Line.level.signals.from.-.18dBu.to.+18dBu.
are.considered.normal..Do.not.directly.connect.microphones.into.
the.equalizers..Microphones.require.a.pre.amp..
Note: Only one input and one output connector should be used at 
a time. 
Rear Panel Controls & Connections
7
9
8
7
8
7
9
8
9