Auralex Acoustics MAX-Wall Manuale Utente

Pagina di 4
Third.  Locking panels together:
The ends of each panel are designed to “peel” 
away (see figure 2), allowing the panels to be 
locked together.  This creates a continuous 
acoustical wall.  Panels can then be hinged 
up to 60°.  When removing these pieces, we 
suggest labeling both the panel and the end 
cap in a location that will be concealed once 
connected.  This will allow you to replace the 
end caps without them being mismatched.  
Our cutting tolerance can vary slightly; end 
caps that are mismatched with panels may 
not  exactly  match,  and  thus  may  not  be  a  perfect  fit  (too 
loose)
.  Decide which set of panels are to be interconnected 
and remove the adjacent end pieces.  Must be male to female 
for this to work.  If you need to, just flip the MAX-Wall panel 
over  so  the  panels 
correctly  connect 
male  to  female 
(figure 3)
.
If  ends  of  panels 
are  adjacent,  but 
hinged 
greater 
than  60°  (actually 
120°  for  you  math-
ematicians)
, leave the end caps on and connect the panels 
together with long pins (clothing, t-pins, etc.) or purchase 
our optional MAX-Wall Corner Couplers.  If the ends of the 
panels are at the end of your setup, we suggest leaving them 
on for appearance reasons!
Optional Accessories:
       1.  Window Unit: 20” x 48” MAX-Wall panel with an 18” 
x 12” Plexiglass window (1⁄4” thick).  The MAX-Wall 
support stand can be adjusted so you can attach a 
microphone gooseneck (as pictured).
       2.  MAX-Wall Corner Couplers
Designed  to  allow  panels  to 
be attached at a 90° (80° to 
100°)
 angle.
MAX-Wall Tips:
End Cap
 
Serving Suggestions:
Figure 2
1.      Some  panels  may  show  a  slight 
variation in color/shade.  This is due to the 
direction of the cut from our production saw.  
Pull  all  of  the  panels  out  of  the  box(es)  and 
mix/match the best combinations.  We suggest 
the closest matches be used on the same stand 
for color consistency.
 
       2.  If  you  need  to  extend  the  height  of  the  MAX-Wall 
beyond  the  capabilities  of  the  MAX-Wall  support 
stand, 5/8” PVC pipe can be placed over the smaller 
diameter top of the stand and cut to a height to sup-
port panels above normal height.
       3.  A more “curved” environment (figure 4).  If you desire 
the MAX-Wall to “surround” you beyond the normal 
hinging  of  the  panels,  you  can “fracture”  the  hole 
lock in the center of the panel, creating a 45° with 
an  individual  panel.    Be  aware  that  the  hole  lock 
can  be  restored,  but  may  not 
be as strong or attractive 
as before.  The “frac-
tured”  panels  are 
best used when the 
ends are interlocked 
with other panels to 
prevent sagging.
       4.  Keep  the  shipping 
box(es) for storage if 
the MAX-Wall will be 
moved around or used intermittently.
Figure 4
Male
Female
Figure 3