Novatel DL-V3 Manuale Utente

Pagina di 208
128
DL-V3 User Manual Rev 3
B.30 METPRESS
Specify Air Pressure
The metpress command allows you to specify air pressure. Air pressure specified with the metpress 
command does not affect receiver operation. Rather, it allows you to create a record of atmospheric 
conditions for post-processing purposes.
The metpress set command specifies air pressure at press. This command only stores the pressure 
value in volatile memory, and does not automatically generate a record. The humidity value can then 
be displayed/recorded by requesting the met log.
The metpress clear and the metpress default commands clear the air pressure setting.
Syntax
metpress set [press]
metpress default|clear
Message ID = 164
 Table 50:  METPRESS Default Configuration
Field
Data
Value Used if 
Not Specified
Bytes
Format
Units
Offset
1
Header
-
-
-
0
2
Parameter Update, see 
Table 34 on Page 107
-
4
Enum
none
H
3
Pressure (in hectopascals or 
kilopascals where:
1 kPa = 10 hPa)
0
4
Float
kPa or 
hPa
a
a. You may use hPa or kPa in your float input depending on your preference
H+4
Parameter
Power-On
Freset
Stored in NVM
metpress
clear
clear
NO