Mitsubishi Electronics MR-J2M-P8B Manuale Utente

Pagina di 195
3 -  7
3. SIGNALS AND WIRING
(2) Detailed description of the interfaces
This section gives the details of the I/O signal interfaces (refer to I/O Division in the table) indicated in
Sections 3.2.2.
Refer to this section and connect the interfaces with the external equipment.
(a) Digital input interface DI-1
Give a signal with a relay or open collector transistor.
V
CES
    1.0V
CE0
    100   A
Interface unit
R: Approx. 4.7k
24VDC
200mA or more VIN
EM1
SG
Switch
For transistor
Approx. 5mA
TR
(b) Digital output interface DO-1
A lamp, relay or photocoupler can be driven. Provide a diode (D) for an inductive load, or an inrush
current suppressing resister (R) for a lamp load. (Permissible current: 40mA or less, inrush
current: 100mA or less)
1) Inductive load
VIN
MBR
SG
24VDC
Interface unit
Load
10%
Opposite polarity of diode
will fail interface unit.