Blaupunkt PCA 250 Manuale Utente

Pagina di 44
Below is a basic trouble-shooting guide to assist in seeking out and correcting a problem that may occur in the installation
process.  Although lengthy, this chart cannot address every single problem possible but mainly the ones most common.  
PARAMETER/FEATURE  
PCA 250
PCA 2100
Channels 2/1
2/1
Size ( W x H x D) 
9.2x2.0x9.5 inches  (234x51x241mm)
9.2x2.0x12.6  (234x51x320mm)
Weight (with housing)
3.5 lbs (1.59 kg)
4.8 lbs (2.18 kg)
Spade screw speaker terminals? 
YES
YES
Maximum terminal wire size 
14 ga.
14 ga.
Subsonic filter 
YES (10 Hz)
YES (10 Hz)
Separate front/rear or left/right gains? 
NO
NO
Fuse Type
ATC spade -20A
ATC spade -Two 20A
Speaker short, short to +12V, and short to ground protection? 
YES
YES
High, low, and reverse voltage protection? 
YES
YES
Power output transistors 
BTL
BTL
Switching power supply transistors 
BTL
BTL
Minimum speaker impedance  
(non-bridged)
2 ohms
2 ohms
(bridged)
4 ohms
4 ohms
PERFORMANCE DATA
Rated power output @ 0.1% THD, 14.4V
2 channels into 4 ohms / 2 ohms 
(watts rms)
2 x 50 W / 2 x 75 W 
2 x 100 W / 2 x 150 W 
1 channel into 4 ohms 
(watts rms)
1 x 150 W
1 x 300 W
Total Harmonic Distortion @ rated full output 
0.1% THD
0.1% THD
Rated Signal/Noise ratio (averaged value)
Measured @ 1 watt / 1 kHz  
dBA
85
85
Measured @ full rated power (0.1% THD)  dBA
>100
>100
Damping factor 
>100
>100
Frequency response (full-range mode) 
20 - 30,000 Hz
20 - 30,000 Hz
High-pass crossover frequency limits 
50 H z - 250 Hz (variable), 12dB/oct
50 H z - 250 Hz (variable), 12dB/oct
Low-pass crossover frequency limits 
50 H z - 250 Hz (variable), 12dB/oct
50 H z - 250 Hz (variable), 12dB/oct
Input impedance 
10 kohms
10 kohms
Input signal voltage control range 
0.3 - 6.0 vrms
0.3 - 6.0 vrms
Current Draw @ 13.8 VDC (typical values @ X watts / Efficiency %)
@ full rated power, unbridged
(@ 4 ohms)
13.3 A (50%)
26 A (52%)
@ 33% rated power, unbridged
(@ 4 ohms)
7.5 A (35%)
15 A (50%)
@ idle 
(@ 4 ohms)
1.5 A
1.5 A
Minimum battery voltage to maintain rated power 
12.6 VDC
12.6 VDC
Usable battery voltage 
10 - 16 VDC
10 - 16 VDC
Trigger line voltage range 
10 - 16 VDC
10 - 16 VDC
Trigger line current draw 
< 10 mA
< 10 mA
Turn on delay time 
@  2.0 seconds
@  2.0 seconds
Thermal shutoff temperature (average heat-sink temp) 
@ 85˚ C (185˚ F)
@ 85˚ C (185˚ F)
NOTE: DUE TO ONGOING PRODUCT IMPROVEMENTS, DESIGN AND SPECIFICATIONS ARE SUBJECT TO CHANGE
WITHOUT ADVANCED NOTICE TO THE CONSUMER OR RETAILER.
B
LAUPUNKT
S
PECIFICATIONS
PCA 250 
AND
PCA 2100, 2/1 C
HANNEL
A