Diagnostic Menus
Use the unit's diagnostic menu to acquire information for troubleshooting purposes. The menus 
also provide test waveforms and use other diagnostic information displayed on an NTSC 
television monitor connected through the back panel’s Video and OSD Video port. Press the  
buttons until the DIAGNOSTIC menu appears. 
Menus Field
Default: Off
Use the Menus field to enable or disable the on-screen diagnostics. Press the4button until the 
cursor is at the MENUS label, and press ENTER to move into the field. Press the  buttons to 
scroll to the desired screen. Press ENTER to confirm the selection and exit the field.
Notice that if the Menus field is set to any option other than Off, Diag F, or Diag G; the Clear Cntrs 
(Clear Counters) field also appears.
Use the  buttons to choose the desired option (Fast Facts 1 through 5 or Diag A through Diag G) 
and press ENTER to confirm the selection and exit the field. For more information about Fast Facts 
screens, see "Diagnostics" on page 85.
Clear Cntrs Field
Use this field to reset selected counters to zero. This field is primarily for use with hotline troubleshoot-
ing, and it is recommended that it be used only when so directed and does not affect the unit’s opera-
tion, but it may give misleading troubleshooting results. To clear counters, press the4button until the 
cursor is at the Clear Cntrs label, and press ENTER to move into the field. Press the  button to select 
Yes and press ENTER to reset the counters to zero and return the field to No.
PR Field (DSR-6402, DSR-6403, and DSR-6404 only)
Default: 1
The PR (processor) field does not appear on a DSR-6401. Press the4button until the cursor is at 
the PR label, and press ENTER to move into the field. While ensuring that the cursor remains on 
the up/down symbol ( ), press the  buttons to scroll throughout the available processor 
values. Press ENTER to confirm the selection and exit the field.
Note:  Changing this value will change all other PR fields throughout this unit’s menu system to 
the same value that is set here. 
  E   Off                       1
DIAG  Menus                  PR
  E    Fact 1     No            1
DIAG   Menus   Clear Cntrs  PR