JAI M4+ CL Manuale Utente

Pagina di 31
CV-M4
+
/M4
+
CL, CV-M7
+
/M7
+
CL
 
 
- 16 - 
 
 
6.5. Edge Pre-select Mode 
The trigger leading edge will start the exposure H synchronous or H a-synchronous (HC=0, HC=1).  
The exposure stops and is read out after the shutter time selected. It can be the 10 steps in 
normal or 1056 steps in programmable. SM=0 or SM=1. This mode will operate with full and 
partial scanning and with V-binning (M4
+
 and M4CL
+
 only). Partial scanning and binning in 
combinations is not allowed. 
In this mode the Restart Continuous Trigger mode (RC=1) can be activated. (By RS-232C and CL  
only). The camera is then running continuously, and it can be reset and restarted by the trigger 
pulse. 
If smearless read out (SL=1) is used, the exposure starts with a delay 133H (5.23 msec.) after the 
trigger. An EEN pulse will indicate the active accumulation time, and a FEN pulse indicates that 
the resulting video is read out. 
 
To use this mode:  
Set function: 
Trigger mode “Edge Pre-select”  
TR = 1 
 
Shutter mode “Normal” or “Programmable” 
SM=0, SM=1 
 
 
“Shutter Speed” 
SH=0 through 9 
 
“Programmable exposure” 
PE=0 through 1057 
 
“H synchronous trigger” 
HC=0, HC=1  
 
“Restart Continuous Trigger” 
RC=0, RC=1 
 “Smearless 
readout” 
SL=0, 
SL=1 
 
 
Polarity and other functions 
Input: 
Ext. trigger to LVDS/Camera Link or pin 10 on 12-pin connector.  
 
 
Important notes on using this mode.
 
•  The duration of the trigger should be >2H to <3V. (>72.64µsec to <120msec). 
•  The minimum trigger interval should be >(exposure time + 1 frame). A new trigger must 
not be applied during the previous frame read out. (Before FEN is high).  
•  Smearless readout cannot be used together with Reset Continuous Trigger.  
 
 
 
Fig. 20. Edge Pre-select