JAI CV-M2 Manuale Utente

Pagina di 35
CV-M2
 
 
- 22 - 
 
 
6.4.5. Burst Trigger mode 
With the burst trigger function, a single trigger pulse can start a sequence with five previous set 
pre-selected programmable exposures. The five shutter times can be set with BSH1 through 
BSH5. (Exposure 1H through 1216H.) The exposure is LVAL synchronous. 
The sequence will start with the first exposure at the first LVAL pulse after the trigger leading 
edge, and the result is read out after the selected shutter time. During the read out of the 
previous frame, the next exposure starts. It will continue until exposure 5 is read out. 
This mode will operate with full and partial scanning.  
An EEN pulse will indicate the active accumulation time, and a FVAL pulse indicates that the 
resulting video sequence is read out. 
 
To use this mode:  
Set function: 
Trigger mode “Burst EPS”  
TR=4 
 
LVAL synchronous accumulation 
LS=0  
 
Burst Shutter 1 
BSH1=1 through 1216 
 
Burst Shutter 2 
BSH2=1 through 1216 
 
Burst Shutter 3 
BSH3=1 through 1216 
 
Burst Shutter 4 
BSH4=1 through 1216 
 
Burst Shutter 5 
BSH5=1 through 1216 
 
Scanning format 
SC=0 through SC=4 
 
Output select 
OS=0, OS=1 
 
Polarity and other functions 
Input: 
Ext. trigger to Camera Link or pin 10 on 12-pin connector.  
 
 
Important notes on using this mode.
 
•  The duration of the trigger should be >2LVAL to <3FVAL.  
•  A new trigger must not be applied before FVAL is low after frame 5. 
•  1LVAL = 47.9 µsec (single). 27.3 µsec (dual). 
 
 
For horizontal timing refer to 6.2.3 through 6.2.6. (Fig.17. through fig. 20.) 
For LVAL synchronous accumulation refer to 6.2.7. (Fig. 21.) 
 
LVAL
DVAL
DATA  OUT
SUB
SG
FVAL
EEN
Ext . Tr i g1
Exposur e
Per i od
Fr ame  1
Fr ame  2
Fr ame  3
Fr ame  4
Fr ame  5
Exp. 1
Exp. 2
Exp. 3
Exp. 4
Exp. 5
 
Fig. 27. Burst Trigger mode