IBM 8688 Manuale Utente

Pagina di 262
Code/Explanation
 
FRU/Action
 
0550h
 
(Read
 
timeout
 
.)
 
1.
   
Confirm
 
that
 
drive
 
is
 
configured.
 
2.
   
Check
 
drive
 
cables
 
and
 
connections.
 
3.
   
Drive.
 
4.
   
I/O
 
board
 
or
 
SCSI
 
add-on
 
controller.
 
0560h
 
(File
 
not
 
found.)
 
1.
   
Check
 
if
 
AMIDiag
 
CD
 
is
 
present
 
in
 
drive.
 
2.
   
Confirm
 
that
 
drive
 
is
 
configured.
 
3.
   
Check
 
drive
 
cables
 
and
 
connections.
 
4.
   
Drive.
 
5.
   
I/O
 
board
 
or
 
SCSI
 
add-on
 
controller.
 
0580h
 
(Cannot
 
allocate
 
memory.)
 
Restart
 
the
 
server
 
and
 
retry.
 
0590h
 
(Command
 
not
 
supported.
 
Unable
 
to
 
run
 
the
 
test
 
on
 
the
 
device.)
 
1.
   
Confirm
 
that
 
drive
 
is
 
configured.
 
2.
   
Check
 
drive
 
cables
 
and
 
connections.
 
3.
   
Drive.
 
4.
   
I/O
 
board
 
or
 
SCSI
 
add-on
 
controller.
   
Video
 
test
 
error
 
codes
  
Code/Explanation
 
FRU/Action
 
0900h
 
(Vertical
 
Synchronization
 
Test
 
failed.)
 
I/O
 
board
 
0901h
 
(Horizontal
 
Synchronization
 
Test
 
failed.)
 
I/O
 
board
 
0902h
 
(Graphics
 
controller
 
test
 
failed.)
 
I/O
 
board
 
0903h
 
(Attribute
 
controller
 
test
 
failed.)
 
I/O
 
board
 
0904h
 
(DAC
 
register
 
test
 
failed.)
 
I/O
 
board
 
0905h
 
(Video
 
adapter
 
memory
 
R/W
 
test
 
failed
 
.)
 
I/O
 
board
 
2100h
 
(Video
 
adapter
 
attribute
 
test
 
failed.
 
)
 
1.
   
Video
 
monitor
 
2.
   
I/O
 
board
 
2102h
 
(Video
 
adapter
 
color
 
test
 
failed.)
 
1.
   
Video
 
monitor
 
2.
   
I/O
 
board
 
2110h
 
-
 
2120h
 
(Param1
 
x
 
Param2
 
mode
 
test
 
failed.)
 
1.
   
Video
 
monitor
 
2.
   
I/O
 
board
   
USB
 
test
 
error
 
codes
 
If
 
any
 
of
 
the
 
following
 
USB
 
errors
 
occur
 
on
 
devices
 
not
 
directly
 
attached
 
to
 
a
 
USB
 
port
 
on
 
the
 
xSeries
 
450
 
(for
 
example,
 
a
 
USB
 
mouse
 
attached
 
to
 
a
 
USB
 
keyboard
 
with
 
an
 
internal
 
USB
 
hub),
 
connect
 
the
 
suspect
 
device
 
directly
 
to
 
the
 
xSeries
 
450
 
and
 
re-run
 
the
 
failing
 
test
 
to
 
isolate
 
whether
 
the
 
failure
 
is
 
with
 
an
 
intermediate
 
device,
 
the
 
device
 
being
 
tested,
 
or
 
the
 
USB
 
subsystem
 
of
 
the
 
xSeries
 
450.
 
In
 
cases
 
where
 
the
 
direct
 
attachment
 
passes,
 
replace
 
the
 
intermediate
 
devices
 
and
 
re-test
 
in
 
the
 
original
 
configuration
 
before
 
replacing
 
the
 
device
 
being
 
tested
 
or
 
the
 
I/O
 
board.
   
Chapter
 
6.
 
Symptom-to-FRU
 
index
 
167