IBM 8688 Manuale Utente

Pagina di 262
Table
 
12.
 
LED
 
error
 
codes
 
for
 
the
 
RXE100
 
port
 
(continued)
 
Error
 
code/symptom
 
FRU/action
 
9023-180-xxx-xxx
 
(Failed
 
RXE
 
PCIX
 
Backplane
 
Side
 
B
 
LED
 
test)
 
1.
   
RXE
 
PCI-X
 
backplane
 
(Side
 
B)
 
2.
   
RXE
 
backplane
 
9024-180-xxx-xxx
 
(Failed
 
RXE
 
Fans
 
LED
 
test)
 
1.
   
RXE
 
fans(s)
 
2.
   
RXE
 
backplane
 
9025-180-xxx-xxx
 
(Failed
 
RXE
 
backplane
 
LED
 
test)
 
RXE
 
backplane
   
Error
 
symptoms
  
Symptom
 
Suggested
 
action
 
CD-ROM
 
drive
 
problems
 
Make
 
sure
 
that:
 
1.
   
The
 
IDE
 
channels
 
are
 
enabled
 
in
 
the
 
Configuration/Setup
 
Utility
 
program.
 
2.
   
All
 
cables
 
and
 
jumpers
 
are
 
installed
 
correctly.
 
3.
   
The
 
correct
 
device
 
driver
 
is
 
installed
 
for
 
the
 
CD-ROM
 
drive.
 
CD-ROM
 
drive
 
is
 
not
 
recognized.
 
Expansion
 
enclosure
 
problems
 
Make
 
sure
 
that:
 
1.
   
The
 
cables
 
for
 
all
 
external
 
SCSI
 
options
 
are
 
connected
 
correctly.
 
2.
   
The
 
last
 
option
 
in
 
each
 
SCSI
 
chain,
 
or
 
the
 
end
 
of
 
the
 
SCSI
 
cable,
 
is
 
terminated
 
correctly.
 
3.
   
Any
 
external
 
SCSI
 
option
 
is
 
turned
 
on.
 
You
 
must
 
turn
 
on
 
an
 
external
 
SCSI
 
option
 
before
 
turning
 
on
 
the
 
server.
For
 
more
 
information,
 
see
 
your
 
SCSI
 
and
 
expansion
 
enclosure
 
documentation.
 
The
 
SCSI
 
expansion
 
enclosure
 
used
 
to
 
work
 
but
 
does
 
not
 
work
 
now.
 
Hard
 
disk
 
drive
 
problems
 
1.
   
Remove
 
the
 
first
 
drive
 
not
 
recognized,
 
and
 
try
 
the
 
hard
 
disk
 
diagnostic
 
test
 
again.
 
2.
   
If
 
the
 
remaining
 
drives
 
are
 
recognized,
 
replace
 
the
 
drive
 
you
 
removed
 
with
 
a
 
new
 
one.
 
Not
 
all
 
drives
 
are
 
recognized
 
by
 
the
 
hard
 
disk
 
diagnostic
 
test
 
(Fixed
 
Disk
 
test).
 
System
 
stops
 
responding
 
during
 
hard
 
disk
 
diagnostic.
 
1.
   
Remove
 
the
 
hard
 
disk
 
drive
 
being
 
tested
 
when
 
the
 
server
 
stopped
 
responding
 
and
 
try
 
the
 
diagnostic
 
again.
 
2.
   
If
 
the
 
hard
 
disk
 
diagnostic
 
runs
 
successfully,
 
replace
 
the
 
drive
 
you
 
removed
 
with
 
a
 
new
 
one.
 
SCSI
 
drives
 
not
 
recognized
 
during
 
POST
 
(loose
 
connection)
 
1.
   
Reseat
 
SCSI
 
cable
 
between
 
I/O
 
and
 
T-docking
 
boards.
 
2.
   
Reseat
 
hard
 
disk
 
drive.
 
CD-ROM
 
drive
 
not
 
recognized
 
by
 
SAL/EFI
 
(loose
 
connection)
 
1.
   
Reseat
 
IDE
 
cable
 
and
 
power
 
cable.
 
2.
   
Ensure
 
that
 
SAL/EFI
 
setup
 
has
 
these
 
devices
 
enabled.
 
Not
 
all
 
drives
 
are
 
recognized
 
by
 
fixed
 
disk
 
diagnostic.
 
1.
   
Remove
 
first
 
drive
 
that
 
does
 
not
 
show
 
up
 
and
 
rerun
 
diagnostic.
 
If
 
remaining
 
drives
 
show
 
up,
 
replace
 
the
 
one
 
that
 
was
 
removed.
 
2.
   
If
 
remaining
 
drives
 
do
 
not
 
show
 
up,
 
remove
 
successive
 
drives
 
one
 
at
 
a
 
time
 
and
 
rerun
 
diagnostic.
 
System
 
hangs
 
during
 
fixed
 
disk
 
diagnostic.
 
Remove
 
hard
 
drive
 
being
 
tested
 
at
 
the
 
time
 
of
 
the
 
hang
 
and
 
rerun
 
the
 
diagnostic.
 
If
 
successful,
 
replace
 
drive
 
that
 
was
 
removed.
   
176
 
IBM
 
xSeries
 
450
 
Type
 
8688:
 
Hardware
 
Maintenance
 
Manual
 
and
 
Troubleshooting
 
Guide