DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Managing multimedia calling 
209
Multimedia Applications Server Interface 
9
terminal. This section sometimes refers to the 
chgmasi
 command. This is the 
command you use to administer MASI parameters on the MMCX. For more 
information about using the chgmasi command, refer to your MMCX Technical 
Reference
Step 1 — Establish customer options (Lucent 
Technologies)
A Lucent Technologies representative must activate MASI using the 
System-Parameters Customer-Options form. The representative should also verify 
that ISDN-PRI (G3r configurations) or ISDN-PRI over PACCON (G3si/csi 
configurations), and AAR/ARS are enabled. 
On the MMCX, MASI must be enabled using the 
chgmasi
 command.
Step 2 — Establish maintenance parameters 
and alarming options (Lucent Technologies) 
Ensure that the Maintenance-Related System Parameters form, Packet Bus 
Activated field = y. 
Using the 
set options
 command (Lucent Technologies init or inads logins only), 
set MASI alarming options. For more information, see DEFINITY ECS 
Maintenance
 for the appropriate model. 
Step 3 — Establish the physical connection 
Establish the physical connection between the DEFINITY ECS and the MMCX. 
For more information about installing the cables, see Installation for Adjuncts and 
Peripherals
Step 4 — Administer circuit pack
Using the DS1 Circuit Pack form, verify that the DS1 circuit pack you use to 
establish the MASI link is administered as follows:
Bit Rate = 1.544
Line Coding = b8zs
Line Compensation = 1
Signaling Mode = isdn-pri
Interface = network
Country Protocol = 1
Protocol Version = a